Device Description HG G-31500-A | English, Revision 02 | Date: 10.06.2021
15
Configuration / Firmware Update – Chapter 5
5
Configuration / Firmware Update
When the device is switched on, the directory SYSTEM is created on a connected
USB storage medium. This directory is used exclusively for system maintenance and
configuration and can contain the following files:
5.1 Release Notes
The file
INFO.TXT
contains information about the installed software.
5.2 Configuration via CONFIG.INI
The factory interface settings can be changed by the user. For this purpose, a text
file CONFIG.INI must be created with the desired settings. Comment lines start with
the # character. Numbers are interpreted decimally or hexadecimally (by prefixing
them with 0x). In case of missing or invalid entries, the respective factory default val
-
ues (see Table 10 on page 17) are taken for setting.
The following settings are possible:
Figure 5
Example: Structure of a CONFIG.INI file
#Config file for audio player HG G-31500A
#CAN
CanExtended = no
CanId = 0x64
CanBitRate = 500000
#UART
UartBitRate = 115200
UartDataBits = 8
UartParity = none
UartStopBits = 1
Table 9
Interface parameters that can be adjusted via CONFIG.INI
Interface
Parameter
Possible values
Unit
CAN Bus
CanExtended no, yes
CanId
All valid identifiers except 0
CanBitRate
1000000, 500000, 250000, 125000,
50000, 20000
[bit/s]
Serial (RS 232) UartBitRate
115200, 57600, 38400, 19200, 9600 [bit/s]
UartDataBits 7, 8
[bit]
UartParity
none, even, odd
UartStopBits 1, 2
[bit]