Device Description HG G-19603ZA | English, Revision 03 | Date: 31.03.2021
17
Commissioning – Chapter 4
4.2 Compensation of Permanent Magnetic Interferences
4.2.1 Compensation of Static Magnetic Interferences
Figure 10
Commissioning: Compensation of static magnetic interferences
NOTICE
Only static interferences can be compensated
The source of the interferences has to move together with the magnet sensor
and its strength may not change.
NOTICE
There is currently no possibility to enable or disable the compensation during
operation! If there is e.g. an electromagnetic brake that emits interferences when
activated but emits no interferences when it is inactive this can not be
dynamically compensated. If a permanent compensation would be set for the
possible interferences the output of the magnet sensor would be off by the
scope of the compensation whenever the brake is inactive.
The compensation is only usable for permanent interferences.
NOTICE
The compensation of interferences limits the range of the magnetic field that can
be used for the track detection.
The magnetic field and the compensated interferences together have to fit
inside the maximum detection range of the magnet sensor.
HG 19603 Serialnumber: 123456 Firmwareversion: V0.01
calibration settings
compensated magnetic field:
system 3 system 2 system 1
0.001 [mT] -0.021 [mT] -0.059 [mT]
-0.046 [mT] -0.054 [mT] -0.044 [mT]
0.013 [mT] 0.019 [mT] 0.022 [mT]
(1) calibrate for track detection
(2) calibrate for static magnetic field
(3) delete static magnetic field compensation
(ESC) QUIT
HG 19603 Serialnumber: 123456 Firmwareversion: V0.01
calibration settings
compensated magnetic field:
system 3 system 2 system 1
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
(1) calibrate for track detection
(2) calibrate for static magnetic field
(3) delete static magnetic field compensation
(ESC) QUIT
HG 19603 Serialnumber: 123456 Firmwareversion: V0.01
calibration settings
compensated magnetic field:
system 3 system 2 system 1
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
reading earth magnetic field...
please TURN OFF static field
please REMOVE all track form the sensor
(1) continue
(ESC) abourt
(ESC) QUIT
HG 19603 Serialnumber: 123456 Firmwareversion: V0.01
calibration settings
compensated magnetic field:
system 3 system 2 system 1
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
0.000 [mT] 0.000 [mT] 0.000 [mT]
reading static magnetic field...
please TURN ON static filed
please REMOVE all track form the sensor
(1) continue
(ESC) abourt
(ESC) QUIT
Key 2
Key 1
Key 1
Example values