Technical Data
English, Revision 03, Date: 11.05.2017
26
4
Technical Data
4.1
Guidance Antenna
4.2
Prerequisites of the Ground Installation
The stationary part of the inductive energy transmission has to match the following pre-
requisites:
Guidance Antenna HG G-19334-A
Casing
Glass-fibre reinforced (GRP)
4 mm aluminium mounting angle
Dimensions
See section A on page 27 in the appendix
Weight
approx. 750 g
Protection class
IP 65
Operating voltage range
18 to 30 V
Current consumption
130 mA
Interfaces
M12 circular plug-in connectors 5-pin
Relative humidity at 25
o
C
95 % (without condensation)
Operating temperature range
0 to +50
o
C
Storage temperature range
-20 to +70
o
C
Mounting height
approx. 35 mm above the energy loop
Table 35
Technical Data Guidance Antenna
Prerequisites
Version
JA
OA
RA
XA
YA
Operating frequency of the
inductive energy transmission
20 kHz
20 kHz
20 kHz
25 kHz
25 kHz
Distance of the twin conductor
80 mm
100 mm
100 mm
140 mm
140 mm
Conductor current of the induc-
tive energy transmission
75 A
75 A
125 A
60 A
85 A
Table 36