![Gotting HG 98860ZA Technical Description Download Page 11](http://html1.mh-extra.com/html/gotting/hg-98860za/hg-98860za_technical-description_2247533011.webp)
Installation / Commissioning
English, Revision 04, Date: 19.01.2015
11
The following diagrams show examples of logged system data:
Figure 7
Diagram: Commissioning Protocol / insignificant interference level; shown is
the sum voltage over the travelled distance
The above diagram shows the sum voltage (in units) over the travelled distance. The
noise is in this case approx. 50 units, the transponder signal approx. 950 units. The
Transponder decoding is perfect, as also shown in the following diagram:
Figure 8
Diagram: Commissioning Protocol / undisturbed Transponder decoding
Low Interference Level
Undisturbed Transponder Decoding