Data Interface CANopen®
English, Revision 06, Date: 12.07.2011
40
5.5
Object Index
All objects relevant for the device are included in the CANopen® Object Index. Each
entry is indicated by a 16 bit index. Sub-components are indicated by a 8 bits subin-
dex. RO indicates only readable entries.
-
Communication parameters are indicated by C in the corresponding tables.
-
Manufacture parameters are indicated by M in the corresponding tables.
The object index is subdivided into the following areas:
5.5.1
Communication specific Entries within the Range of 0x1000
to 0x1FFF
Name
Number
Description
SDO_ABORT_UNSUPPORTED
0x06010000
non-supported access to an object
SDO_ABORT_READONLY
0x06010001
write access to a read-only object
SDO_ABORT_NOT_EXISTS
0x06020000
object not implemented
SDO_ABORT_TRANSFER
0x08000020
The signature ’load’ or ’save’ was not used for load-
ing or saving parameters.
SDO_ABORT_PARA_VALUE
0x06090030
Parameter value range exceeded
SDO_ABORT_PARA_TO_HIGH
0x06090031
Parameter value too high
Table 11
Error codes
Index
Subindex
Access
Content
EEProm
0x1000
0
RO
Device Type
0x1001
0
RO
Error Register
0x1005
0
RO
COB ID Sync Message
0x1008
0
RO
Device Name
0x1009
0
RO
Hardware Version
0x100A
0
RO
Software Version
0x1010
0
RO
Number of entries of Save Parameter
1
RW
Save all
Table 12
Overview of the object dictionary (part 1 of 2)