4.4
(O)utput-Input Settings
This menu offers the option of switching between OUT_1 to OUT_4. According to the
selection of menu point (
) these outputs will be used as indicators for the edgewise
deviation or as the code output for the low-ordered 4 bits of the bar code.
In the following figure the outputs OUT_1...OUT_4 were selected for the code output:
Figure 12
Screenshot: Menu (O)utput-Input Settings - output of threshold
The menu points (
) and (
) have here the following meanings:
-
By using
the time lag of the code output from OUT_1..OUT_4 to DATA_READY
pulse to OUT_5 can be chosen.
-
With
the duration of the DATA_READY pulse to OUT_5 can be set.
In the following figure the outputs OUT_1...OUT_4 will be used as indicators for edge-
wise deviation:
Peak 27889 @ 265 X/mm: 4 S: 4000 Code: 255 SCmin: 0 %
Parallel Output:
(X)-Deviation on OUT_1..OUT4
(1)CODE_OK (OUT_5) setup time [1..100 ms]: 20
(2)CODE_OK (OUT_5) duration [1..1000 ms]: 100
Parallel Input:
(P)arallel input active 1
(D)ebounce time [0..100ms]: 50
Analog Output:
(A)mplitude [-10..10V]: 10.00
(O)ffset [-5V..0..5V]: 0.00
(H)old analog value on loss of track 0
(B)ridge a track gap (n*20 ms) [0..25]: 20
Bridge a track (J)ump (n*20 ms) [0..25]: 0
Jump (I)ncrement [1..100 %]: 100
(Q)uit