<cell_id>: Cell identify
<lac_id>: Location Area Code
<pci> Physical cell ID
<sinr> Serving cell SINR information
<rx_power> Receiving Signal strength in dBm
<tx_power> TX power information
<ecio> Pilot Strength
<imsi_buf>: International Mobile Station ID (IMSI)
Example
2.
When registered to LTE network:
AT+ZCDS?
+ZCDS:1675,460,1,911B,BB75A31,-99,99,14,-8,363,460019011339325
OK
3.
When registered to GSM network:
AT+ZARFCN?
GSM: 108
OK
AT+ZCDS?
+ZCDS:108,460,1,20E6,C8C4,-61,33,0,0,460019011339325
OK
4.
When registered to UMTS network:
AT+ZPAS?
+ZPAS: "UMTS","CS_PS"
OK
AT+ZCDS?
+ZCDS:10713,460,1,BB1D,C1D30FF,199,99,0,0,460019011339325
OK
AT+ZARFCN?
UMTS: 10713
OK
7.18.
AT+ZSRSP Query RSRP,RSRQ,SINR of the main cell
This command is used to query the RSRP,RSRQ,SINR of the module’s main cell.
Note: This command is only valid when the module register to LTE network.
This command is only supported by module ME3630-E.
Command
Response
+ZSRSP?
<CR><LF>+ZSRSP:<rsrp >,< rsrq>,<rssi >,<sinr><CR><LF>