7. Defrosting
• After prolonged use, your GoSun Chill may start to accumulate frost on the
inside. If the frost gets more than 1/2” (12.5mm) thick it is recommended to
defrost the Chill to maximize energy efficiency. To defrost the Chill, remove any
contents temporarily and place somewhere cool to minimize heat gain.
• Fast method: Turn off the Chill. Use a plastic tool such as a car ice scraper, and
physically remove the frost from inside the Chill. Then wipe up and residual
5. Error Codes
•
F1 Code -
Low battery voltage. Your battery has been drained and needs to
be recharged. Charge your power source and reconnect to the Chill. Ensure
that the correct battery protection setting is used (see section 3.4).
•
F2 Code -
Fan overload. Turn off the Chill and let rest for 15-30 min. Restart
the Chill. If the error persists, contact GoSun Support.
•
F3 Code -
Compressor protection activated. Turn off the Chill and let rest for
30 min. Restart the Chill. If the error persists, contact GoSun Support.
•
F5 Code -
Compressor controller module protection activated. Turn off the
Chill and let rest for 30 min. Restart the Chill. If the error persists, contact
GoSun Support.
•
F7/F8 Code -
Temperature sensor error. Turn off the Chill and let rest for 30
min. Restart the Chill. If the error persists, contact GoSun Support.
5
6. Function & Operation Settings – Advanced
To change the GoSun Chill’s Advanced Settings, hold the setting button
when the GoSun Chill is powered off, but still connected to power. E1 will
flash on the screen, press the settings button to cycle through from E1
through E9. To change a setting press the up or down buttons.
Setting
E1
E2
E3
E4
E5
E6
E7
E8
E9
Function
Temp sensor compensation >7C
Fahrenheit or Celsius setting
Soft Start Setting
Hysteresis
(deviation from set point before restarting)
Maximum Temperature Setting
Minimum Temperature Setting
Factory only setting, do not change.
Temp sensor compensation -7 to -12C
Temp sensor compensation <-12C
Setting Range Default Setting
-40 to Set E2
-20
20
3
0
F
0
0
0
N/A
Set E1 to 40
1 to 10
0 to 10
F or C
-10 to 10
-10 to 10
-10 to 10
N/A
water/ice with a towel. Turn the Chill back on and place any items you
removed earlier back into the Chill.
• DO NOT USE METAL TOOLS on the inside of the Chill as they can cause perma-
nent damage to the inside walls and refrigerant lines.
• Slow method: Turn off the Chill and leave the lid open. Just wait for the ice to
melt and remove the remaining water with a towel, or use the built in drain in
the bottom of the Chill. Turn the Chill back on and place any items you
removed earlier back into the Chill.
• DO NOT TRY TO POUR OUT THE MELTED ICE, the cooler should not be tilted
past 30 degrees from flat, as this will allow liquid refrigerant to gain access to
the compressor which can damage the Chill.