Printed in Germany • Subject to change without notice
GOSSEN METRAWATT GMBH
Thomas-Mann-Str. 16-20
90471 Nürnberg, Germany
Phone +49-(0)-911-8602-0
Fax
+49-(0)-911-8602-669
E-mail [email protected]
www.gmc-instruments.com
Technical Data
For complete technical data refer to the following data sheet:
order no. 3-349-202-03
Annual mean relative humidity, no condensation
75%
Ambient temperature
Nominal range of use
Operating range
Storage range
0
°
C ... + 50
°
C
0
°
C ... + 50
°
C
–25
°
C ... + 70
°
C
Aux. Voltage
Nominal Ranges of Use
Power Consumption
Nominal Value
Voltage
Frequency
AC 110 V /
AC 230 V
AC 95 V ... 253 V
48 Hz ... 62 Hz
Max. 10 VA
typically 6 W
Relay Output
Floating, normally open contact
Switching capacity
AC/DC 250 V, 2 A, 500 VA / 50 W
Service life
> 2
•
10
5
switching cycles at nominal load
Interference suppression
Utilize external RC element (100
Ω
- 47 nF)
at contactor
Transistor output suitable for commercially available semiconductor relays (SSR)
Switching Status
Open-Circuit Voltage
Output Current
Active (load
≤
800
Ω
)
< DC 17 V
10 ... 15 mA
Inactive
< DC 17 V
< 0.02 mA
Overload limit
Short-circuit, continuous interruption
Electrical Safety
Safety class
II, panel-mount device, DIN EN 61010-1 section 6.50.4
Fouling factor
1, per DIN EN 61010-1 section 3.7.3.1 and IEC 664
Overvoltage category
II, per DIN EN 61010 appendix J and IEC 664
Operating voltage
300 V per DIN EN 61010
EMC requirements
IEC/EN 61 326