Queriable Functions and Parameters
Read out via interface
Response string for remote operation
(example):
Resp.
string
length
Expla-
nation
in
chap.
on
page
Front panel
1)
RS 232C
IEEE 488
10 characters 10 characters 10 characters
Measured V
a
lue Quer
y
I
Max. measured current value from Min-Max memory [A]
X
IMA
X?
X
X
IMAX +045. 440
13
I_
Min. measured current value from Min-Max memory [A]
X
IMI
N?
X
X
IMIN -000. 010
13
Iout LED
Momentary measured current value [A]
X
IO
UT? + display
X
X
IOUT +031. 510
13
CV/CC/Pmax LED
Momentary output operating mode (control mode)
X
2)
MO
DE?
CV = constant voltage, CC = constant current
X
X
MODE
CV
8
OL = overload, OFF = output deactivated
Pout + Display LED
Momentary measured power value [W]
X
POU
T?
X
X
POUT +0662 .7
12
U
Max. measured voltage value from Min-Max memory [V]
X
UMA
X?
X
X
UMAX +021. 310
13
U_
Min. measured voltage value from Min-Max memory [V]
X
UMI
N?
X
X
UMIN +021. 280
13
Uout + Display LED
Momentary measured voltage value [V]
X
UO
UT?
X
X
UOUT +021. 300
13
Function-Specific Device Queries
DELAY + Display LED
Selected delay time for OCP function
X
DE
LAY?
X
X
DELAY 12.0 0
11
DI
SPLAY?
On-off status of the 7-segment displays
X
X
DISPLAY
O N
11
Ilim + Display LED
Selected current setting range limit [A]
X
IL
IM?
X
X
ILIM +050. 000
13
Iset + Display LED
Selected current setpoint value [A]
X
IS
ET?
X
X
ISET +048. 000
13
UI_
Min-max memory enable status
X
MI
NMAX?
X
X
MINMAX
ON
10
OCP
Selected current limiting function
X
OC
P?
X
X
OCP OFF
7
OUTPUT LED
Output on-off status
X
2)
OU
TPUT?
X
X
OUTPUT
ON
10
OVset + Display LED
Selected overvoltage protection trigger value [V]
X
OVS
ET?
X
X
OVSET +050 .0
12
Pon
Selected power-on status
X
POW
ER_ON?
X
X
POWER_ON R ST
12
reP
Selected number of repetitions for the SEQUENCE function
X
RE
PETITION?
X
X
REPETITION
000
14
READY LED
4)
SEQUENCE function status
X
rcl + rrEP
SEQ
UENCE?
X
X
SEQUENCE H OLD,255,11
1
21
Strt
Selected start and stop memory addresses for the SEQUENCE function
X
3)
StoP
STA
RT_STOP?
X
X
START_STOP
020,115
18
STO
RE?
Recall data from start address to stop address from SEQUENCE memory
5)
X
X
STORE 014, +015.500,+ 003.000,09
STO
RE?
n
Recall data from address n from SEQUENCE memory
STO
RE?
n1,n2
Recall data from address n1 to address n2 from SEQUENCE memory
STO
RE?
n1,n2,txt
Recall data from address n1 to address n2 from SEQUENCE memory with tab
37
6)
n, n1, n2:
11, 12, ... , 255 (memory address), n2
≥
n1, optional
txt:
tab (optional)
.70, NC
tdEF
Selected default time for the SEQUENCE function
X
TD
EF?
X
X
TDEF 10.00
10
trG
Selected trigger input function
X
T_M
ODE?
X
X
T_MODE OUT
10
tSEt
Selected dwell time for the SEQUENCE function
X
TS
ET?
X
X
TSET 00.10
10
Ulim + Display LED
Selected voltage setting range limit [V]
X
UL
IM?
X
X
ULIM +035. 000
13
Uset + Display LED
Selected voltage setpoint value [V]
X
US
ET?
X
X
USET +021. 300
13