GMC-I Gossen-Metrawatt GmbH
59
Terminating Device Messages
a) For IEEE 488 remote control
The following end-of-text characters can be used for data
receive:
NL
New line = line feed = (0A
h
)
NL & EOI
EOI = end or identify
DAB & EOI
DAB = last data byte
The still common end-of-message character combination CR
LF (0D
h
followed by 0A
h
) should no longer be used according
to the standard. Although it is accepted by the device for data
receive, it should be used in combination with EOI.
The following end-of-message character is used when
transmitting the response string:
NL & EOI.
b) For RS 232C remote control
The following end-of-text characters can be used for data
receive:
NL
(0A
h
) = new line = line feed
CR
(0D
h
) = carriage return
CR LF
Carriage return and line feed
ETB
(17
h
)
ETX
(03
h)
The following end-of-message character is used when
transmitting the response string:
NL
(0A
h
) = new line = line feed
6.2 IEEE 488 Functions
6.3 Overview
The following table provides an overview of device-specific setting and query commands.
A detailed description of the respective device function is included in the next chapter, arranged in alphabetical order.
Command Overview According to Application
Abbreviation
Term
Meaning
SH1
SOURCE HANDSHAKE
Handshake source function
AH1
ACCEPTOR HANDSHAKE Handshake sink function
T6
TALKER
Talker function with series polling and
automatic unlisting, without secondary
address and without talk-only mode
L4
LISTENER
Listener function with automatic unlisting
without secondary address and without
listen-only mode
TE0
No extended talker function
LE0
No extended listener function
SR1
SERVICE REQUEST
Service request function
RL1
REMOTE/LOCAL
Switching to and from manual and remote
operation, with local lockout
DC1
DEVICE CLEAR
Rest function including selected device clear
PP1
PARALLEL POLL
Parallel polling function with remote
configuring
DT1
DEVICE TRIGGER
Trigger function
C0
No controller function
E1 / 2
Open collector driver
IDENTIFICATION / CONFIGURATION
• *IDN?
BASIC FUNCTIONS
Extended BASIC FUNCTIONS
MONITORING AND PROTECTION Functions
Setpoints
• USET
• ISET
• OUTPUT
• POWER_ON
Measured Value Query
• UOUT
• IOUT
• POUT
• *RST
• *SAV
• *RCL
• *LRN
• T_MODE
• DISPLAY
• WAIT
• ULIM
• ILIM
• OVSET
• MINMAX
• UMIN
• UMAX
• IMIN
• IMAX
• OCP
• DELAY
• MODE
• CRA
• ERA
• ERB
SEQUENCE and
STEP-BY-STEP CONTROL FUNCTIONS
Time Dependent FUNCTIONS,
External CONTROL
Special COMMANDS
STATUS and EVENT MANAGEMENT
Sequence Control
• SEQUENCE
• START_STOP
• REPETITION
• TDEF
• TSET
Memory Management
• STORE
• *SAV
• *RCL
• T_MODE
• OCP
• DELAY
• *DDT
• *TRG
• WAIT
• *TST
• HID_TST
• IFC
• SDC
• DCL
• *WAI
• *CLS
• *STB, *SRE
• *ESR, *ESE
• *IST, *PRE
• *OPC
• *PSC
Condition and Event Register
• CRA
• ERA, ERAE
• ERB, ERBE