The heat pump offers various installation options of connection of the air inlet and outlet pipelines. We recommend the connection
options, which enable the simplest installation of the appliance to the pipeline system. When designing the pipeline system for air
inlet and outlet to and from the heat pump it is essential to consider the aerodynamic characteristics of the heat pump fan, where
the static pressure loss occurs.
The aerodynamic characteristics are displayed in a graph as a pressure drop in relation to airflow. The operating point of the heat
pump fan is at 100 Pa of static pressure or at airflow of 330 m
3
. Working drop of static pressure in an air pipeline of heat pumps
is considered
Δ
p= 100 Pa. If the calculations show higher pressure drops, the fan speed can be increased. The increase of the fan
speed is effective up to 80%. The airflow does not increase above this level, therefore we advise against further increase for it will
only cause higher levels of noise.
The diagram shows the following areas:
• High-efficiency area – area of high airflow rates (over 300 m
3
) requires lower pressure drops (pipeline free or short pipeline) and
fan settings to 60% or 80%.
• Middle-efficiency area – area of middle airflow rates (between 200 and 300 m
3
/h), 40% fan settings, minimum pressure drop,
60% or 80% of settings and pressure drops between 50 and 300 Pa.
• Expanded area for higher ambient temperatures – a wider range of settings and high pressure drops.
These settings may be in
use only with air temperature over 20°C,
otherwise an efficiency decline occurs.
DETERMINING PRESSURE LOSS IN THE AIR INLET AND OUTLET PIPELINE SYSTEM
Figure 4:
Aerodynamic characteristics of heat pump fan
0
700
650
500
550
400
450
400
350
300
250
200
150
100
50
0
20
40
60
80
100 120 140 160 180 200 220 240 260 280 300 320 340 360 380 400 420 440 460 480 500
High-efficiency area
Airflow [m
3
/h]
Pressure difference [Pa]
40 %
80 %
60 %
Middle-efficiency area
Expanded area for higher ambient temperatures
operation point
25
EN
542916
Summary of Contents for TC 200: TC 300
Page 1: ...www gorenje com INSTRUCCIONES DE USO INSTRUCTIONS FOR USE TC 200 300 C o EN ES ...
Page 38: ...542916 38 ...
Page 39: ...542916 39 ...
Page 40: ...TC 200 300 05 2017 542916 ...