444650
Gas type, pressure
Auxiliary
burner
Normal
burner
Large burner
Double
burner
max
min
max
min
max
min
max
min
Natural gas H
Wo=45,7÷54,7 MJ/ m
3
,
Natural gas E, E+
Wo=40,9÷54,7 MJ/m
3
G20,
p=20mbar
Rated power
(kW)
1
0,36
1,9
0,46
3
0,76
3,5
1,56
Gas
consumption
(l/h)
95,21
34,4
180,9
43,8
285,64
72,4
333,2
148,5
Nozzle type
(
μm
) / Bypass
No.
78
24
104
26
129
33
135
57
Nozzle ID
431006
162083
431008
431245
Liquid gas 3+, 3B/P
Wo=72,9÷87,3MJ/m
3
G30
p=30 mbar
Rated power
(kW)
1
0,36
1,9
0,46
3
0,76
3,5
1,56
Gas
consumption
(g/h)
71,7
26,2
138,1
33,4
215
55,3
254,5
113,4
Nozzle type
(
μm
) / Bypass
No.
50
24
69
26
87
33
93
57
Nozzle ID
162162
162164
162165
162166
• Regulation valves that are factory-built-in are intended for liquid gas; however, the
valves are set for operation with the type of gas for which the appliance is factory-
preset.
• When adapting the appliance for use with another type of gas, the regulation screw
(valve) should be fastened or release to correspond with the required gas fl ow /
throughput (however, the regulation screw should not be released more than by 1.5
rounds from the position in which it is completely fastened).
Burner power is indicated by observing the upper Hs caloric value.
Warning: these tasks may only be carried out by a qualifi ed technician, authorized by
the gas distributing company or authorized service center!
23
NOZZLE TABLE