CHAPTER 3. TECHNICAL DESCRIPTION
GÖPEL electronic GmbH
ground of the power supply is on earth. The power adapter has the following specifications:
Table 3.8: Spezifications of the Power Adapter
Property
Value
Unit
Comment
Model
BET-0600
Cable length
1.5
m
AC Input voltage
90 .. 264
V
DC Output voltage
12
V
DC Output current
5000
mA
Operating temperatur
-20 .. +60
°C
Power
60
W
Ripple
120
mV
Peak to peak
Weight
300
g
Type of input connector
IEC socket
The device-side connector is a 3-pin M8 socket from PHOENIX CONTACT (Item No. 1456035; plug side: 1681172).
Figure 3.5: Schematic drawing of the socket of the power supply
The following table shows the pin assignment of the connector:
Table 3.9: Pin assignment of the power supply
Pin
Signal
Housing
GND_SHELL
1
V_ISO_IN
3
GND_ISO_IN
4
GND_SHELL
When delivered,
GND_SHELL
and
GND_ISO
are not connected. Between the two signals is only a 100nF
/ 250V ceramic capacitor. Please place the signal
GND_SHELL
on the test objects ground or earth.
3.4.6 Galvanic Isolation
Overvoltages can damage expensive test equipment or lead to unsafe test results. The potential separation
protects against overvoltages and can suppress dangerous surges. It also prevents ground loops responsible for
G CAR 6282
15