Goodman GSZ 14 SEER Technical Manual Download Page 1

GSZ 14 SEER

Split System Heat Pumps

Refer to Service Manual RS6200006 for installation, operation, and troubleshooting information.

All safety information must be followed as provided in the Service Manual.

Refer to the appropriate Parts Catalog for part number information.

Models listed on page 3.

RT6213007

February 2011

Copyright © 2011 Goodman Manufacturi

ng Company, L.P.

®

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANUAL

AL

AL

AL

AL

This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does
not assume any responsibility for property damage or personal injury due to improper service
procedures or services performed by an unqualified person.

Summary of Contents for GSZ 14 SEER

Page 1: ...number information Models listed on page 3 RT6213007 February2011 Copyright 2011 Goodman Manufacturing Company L P TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL...

Page 2: ...any jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING ONLY individuals meeting at a mininum the requirements of an Entry Leve...

Page 3: ...e with this unit Serious property damage personal injury reduced unit performance and or hazardous conditions may result from the use of such non approved devices WARNING WARNING To prevent the risk o...

Page 4: ...re tolerant of small quantities of liquid refrigerant NOTE Even though the compressor section of a Scroll com pressor is more tolerant of liquid refrigerant continued floodback or flooded start condit...

Page 5: ...d TXV Kit to be installed on the indoor coil THE SPECIFIED TXV IS DETERMINED BY THE OUTDOORUNIT NOTTHEINDOORCOIL GSZ140181A GSZ140601A GSZ140181A GSZ140241A GSZ140301A GSZ140361A GSZ140421A GSZ140481A...

Page 6: ...16 3 17 7 19 0 14 7 15 1 16 4 17 6 S T 0 84 0 75 0 57 0 36 0 87 0 78 0 59 0 38 0 89 0 80 0 60 0 39 0 92 0 82 0 62 0 40 0 95 0 85 0 65 0 42 0 96 0 86 0 65 0 42 Delta T 20 19 15 11 21 19 16 11 21 19 16...

Page 7: ...4 252 266 277 266 286 302 315 303 326 344 359 341 367 387 404 376 405 428 446 LO PR 104 111 121 129 110 117 128 136 115 122 133 142 120 128 140 149 126 134 147 156 131 139 152 161 MBh 18 6 18 9 19 8 2...

Page 8: ...25 3 19 6 20 2 21 8 23 4 S T 0 86 0 77 0 58 0 37 0 89 0 79 0 60 0 39 0 91 0 81 0 62 0 40 0 94 0 84 0 64 0 41 0 98 0 87 0 66 0 42 0 98 0 88 0 67 0 43 Delta T 20 18 15 10 20 18 15 10 20 18 15 10 20 19...

Page 9: ...277 289 278 299 315 329 316 340 359 375 356 383 404 422 393 423 447 466 LO PR 108 115 125 133 114 121 132 141 118 126 138 146 124 132 144 154 130 139 151 161 135 143 157 167 MBh 24 8 25 2 26 4 28 2 24...

Page 10: ...26 1 28 3 30 3 23 5 24 2 26 2 28 1 S T 0 89 0 80 0 61 0 39 0 93 0 83 0 63 0 40 0 95 0 85 0 64 0 41 0 98 0 88 0 66 0 43 1 00 0 91 0 69 0 44 1 00 0 92 0 69 0 45 Delta T 20 18 15 10 20 19 15 11 20 19 15...

Page 11: ...43 261 276 287 276 297 313 327 314 338 357 372 353 380 402 419 390 420 444 463 LO PR 110 117 127 136 116 123 135 143 120 128 140 149 126 135 147 156 133 141 154 164 137 146 159 170 MBh 29 7 30 3 31 7...

Page 12: ...0 25 6 26 3 28 5 30 6 S T 0 82 0 74 0 56 0 36 0 85 0 76 0 58 0 37 0 87 0 78 0 59 0 38 0 90 0 81 0 61 0 39 0 94 0 84 0 63 0 41 0 95 0 85 0 64 0 41 Delta T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 1...

Page 13: ...03 316 303 326 344 359 345 371 392 409 388 417 441 460 429 461 487 508 LO PR 115 122 133 142 121 129 141 150 126 134 146 156 132 141 154 164 139 148 161 172 144 153 167 178 MBh 32 4 33 0 34 6 36 9 31...

Page 14: ...6 33 6 36 4 39 0 S T 0 88 0 79 0 60 0 38 0 91 0 82 0 62 0 40 0 94 0 84 0 63 0 41 0 97 0 86 0 65 0 42 1 00 0 90 0 68 0 44 1 00 0 90 0 68 0 44 Delta T 20 19 15 11 21 19 16 11 21 19 16 11 21 19 16 11 21...

Page 15: ...39 257 272 284 272 293 309 322 310 333 352 367 349 375 396 413 385 414 438 456 LO PR 105 112 122 130 111 118 129 138 116 123 134 143 121 129 141 150 127 135 148 157 132 140 153 163 MBh 41 3 42 1 44 1...

Page 16: ...7 45 1 48 5 37 5 38 6 41 8 44 9 S T 0 87 0 78 0 59 0 38 0 90 0 80 0 61 0 39 0 92 0 82 0 62 0 40 0 95 0 85 0 64 0 41 0 99 0 88 0 67 0 43 1 00 0 89 0 67 0 43 Delta T 21 19 16 11 21 20 16 11 21 20 16 11...

Page 17: ...9 257 271 283 271 292 308 322 309 333 351 366 348 374 395 412 384 413 436 455 LO PR 104 110 121 128 110 117 127 136 114 121 132 141 120 127 139 148 125 133 146 155 130 138 151 160 MBh 47 5 48 4 50 7 5...

Page 18: ...5 59 5 46 1 47 5 51 4 55 1 S T 0 84 0 75 0 57 0 37 0 87 0 78 0 59 0 38 0 90 0 80 0 61 0 39 0 93 0 83 0 63 0 40 0 96 0 86 0 65 0 42 0 97 0 87 0 66 0 42 Delta T 21 19 16 11 21 20 16 11 21 20 16 11 21 2...

Page 19: ...1 259 274 285 274 295 311 325 312 336 354 370 351 378 399 416 388 417 441 460 LO PR 101 107 117 125 107 113 124 132 111 118 129 137 116 124 135 144 122 130 142 151 126 134 147 156 MBh 58 3 59 4 62 2 6...

Page 20: ...294 85 57 913 41 472 16 440 4 428 90 57 206 41 626 15 580 4 547 95 56 500 41 764 14 736 4 666 100 55 088 41 492 13 596 4 767 105 53 675 41 180 12 495 4 868 110 51 698 39 829 11 869 4 955 115 49 720 3...

Page 21: ...3 35 3 16 2 81 2 65 2 50 2 39 2 33 2 14 1 94 1 73 1 52 1 28 EER 14 5 14 0 13 4 12 8 12 4 12 1 11 4 10 8 9 6 9 1 8 5 8 2 7 9 7 3 6 6 5 9 5 2 4 4 HI PR 373 358 344 329 321 315 303 290 278 266 255 249 24...

Page 22: ...30 25 20 17 15 10 5 0 5 10 MBh 57 8 54 7 51 5 48 2 46 0 44 6 41 4 38 2 36 6 33 8 31 1 29 4 28 3 25 4 22 5 19 6 16 8 13 7 Delta T 34 5 32 7 30 8 28 8 27 5 26 6 24 7 22 8 21 9 20 2 18 6 17 6 16 9 15 2...

Page 23: ...01 Basic Unit without Auxiliary Heat Capacity of Unit With KW of Auxiliary heat Outdoor Ambient F Model SZ140301A CA F3642 6A TXV MBR1600 1 Conditions 1050 CFM Indoor Air 70 F DB capacity btuh c o p...

Page 24: ...0 55 106 93 35 38 18 3 17 54 56 70 94 87 33 103 71 30 36 62 2 94 53 00 69 38 85 76 102 15 25 33 80 2 77 50 18 66 56 82 94 99 32 20 31 12 2 61 47 50 63 89 80 27 96 65 15 28 30 2 43 44 68 61 06 77 45 93...

Page 25: ...ht increase will occur in indoor temperature drop Delta T A slight decrease will occur in low and high side pressures and power A properly operating unit should be within plus or minus 2 degrees of th...

Page 26: ...S LOW PRESSURE SWITCH LVDR LOW VOLTAGE DEFROST RELAY LVJB LOW VOLTAGE JUNCTION BOX RCCF RUN CAPACITOR FOR COMPRESSOR FAN RVC REVERSING VALVE COIL SA START ASSIST SC START CAPACITOR FOR COMPRESSOR OPTI...

Reviews: