Refer to Service Manual RS6200006 for installation, operation & troubleshooting information.

All safety information must be followed as provided in the Service Manual.

Refer to the appropriate Parts Catalog for part number information.

Models listed on page 3.

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANU

TECHNICAL MANUAL

AL

AL

AL

AL

RT6121004r2

March  2014

Copyright © 2013-2014 Goodman Manufa

cturing Company, L.P.

This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury due to improper
service procedures or services performed by an unqualified person.

AVPTC Air Handlers

Summary of Contents for AVPTC24B14A

Page 1: ...d on page 3 TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL AL AL RT6121004r2 March 2014 Copyright 2013 2014 Goodman Manufacturing Company L P This manual is to be used by qualified professionally trained HVAC technicians only Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed...

Page 2: ...cedures If you install or perform service on this unit you assume responsibility for any personal injury or property damage which may result Many jurisdictions require a license to install or service heating and air conditioning equipment WARNING WARNING WARNING WARNING All Airhandlers use DIRECT DRIVE MOTORS Power supply is AC 208 230v 60 hz 1 phase A V P T C 24 B 1 4 A A PRODUCT TYPE A Air Handl...

Page 3: ...ammable liquids or vapors in the vicinity of this appliance WARNING WARNING When installing or servicing this equipment safety clothing includ ing hand and eye protection is strongly advised If installing this equipment in an area that has special safety requirements hard hats etc ob serve these requirements To protect the unit when braz ing close to the painted surfaces the use of a quenching clo...

Page 4: ...ed spaces where sweating may occur Appliances installed in garages warehouses or other areas where they may be subjected to mechanical damage must be suitably guarded against such damage by installing be hind protective barriers being elevated or located out of the normal path of vehicles When installed on a base the base must also be protected by similar means Heating and cooling equipment locate...

Page 5: ...PRODUCT DIMENSIONS 5 AVPTC ...

Page 6: ...24 000 30 000 36 000 42 000 42 000 48 000 60 000 CFM High range 1100 600 1200 600 1600 700 1660 700 1700 800 1800 1350 2000 1600 Blower Diameter 10 10 10 10 10 10 11 Width 6 8 10 10 10 10 10 Coil Drain Connect FPT Refrigerant Line Connection Size Liquid Suction Electrical Data Voltage 208 240 208 240 208 240 208 240 208 240 208 240 208 240 Electric Heat Capacity kW 3 5 6 8 10 3 5 6 8 10 5 6 8 10 1...

Page 7: ...tion for details 2 Airflow blink codes are approximations of actual airflow Profiles Pre Run Short Run OFF Delay C OFF ON OFF ON OFF ON C 7 5 min 82 60 sec 100 D 30 sec 50 7 5 min 82 30 sec 50 To Set Comfort mode Select desired Comfort Mode Profile see profiles above Set dip switches S5 and S6 to appropriate ON OFF positions Dehumidification To enable set dip switch S7 to ON Cooling airflow will b...

Page 8: ...cfm speed tap of ON OFF ON For match up with a 3 5 ton outdoor unit Heater kit application shall not exceed 20 kW Airflow for 5 kW up to 20 kW heater kits shall be set to 1500 cfm speed tap of ON OFF OFF 3 kW heater kit is not applicable for this indoor application Htr kW 9 10 11 AVPTC24B14A AVPTC30C14A AVPTC36C14A AVPTC48C14 AVPTC42D14A AVPTC48D14A AVPTC60D14A 3 ON ON ON 730 730 NR NR 850 NR NR 5...

Page 9: ...CALL 1 BK 3 M1 W1 RD L2 8 9 R2 HTR2 5 M2 W1 1 M4 BK C L1 8 TWO 2 ELEMENT ROWS RD DEHUM TX 3 BL TWO STAGE INTEGRATED CONTROL MODULE TL 3 GND TL NOTE WHEN INSTALLING HEATER KIT ENSURE SPEED TAP DOES NOT EXCEED MINIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIRHANDLER HEATER HTR2 BL R 6 HEAT SEQUENCER R2 RD TRANSFORMER RD FL YL M7 24 V THERMOSTAT CONNECTIONS 2 HEAT SEQUENCER R1 GN 7 WH TR BK RD FL 2 FL L...

Page 10: ...IT ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM BLOWER SPEED MBS SPECIFIED FOR THE AIRHANDLER HEATER KIT COMBINATION ON THIS UNIT S SERIAL PLATE AFTER INSTALLING OPTIONAL HEAT KIT MARK AN X IN THE PROVIDED BELOW NO MARK INDICATES NO HEAT KIT INSTALLED FIVE 5 ELEMENT ROWS NOTE THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION BK RD BK RD 3 Phase Heat Kit 25kW Heat Kit AVPTC...