Menu Options
LED Display
Menu Description
gtF
Gas Heat Airflow Trim (default = 0%)
HdI
Maximum Compressor Run Time Between Defrost Cycles (default
= 120 minutes)
HFd
Heat Pump Heating Airflow Off Delay Time (default = 60 seconds)
Hnd
Heat Pump Heating Airflow On Delay Time (default = 5 seconds)
HP
Select the range that includes the desired compressor RPS for
inverter heating operation. See inverter manual for menu options
H
Maximum Compressor RPS for Heating Mode (inverter only)
Ht
Reset all heat pump heating settings to factory default.
Ht
Percentage of high stage heat pump heating airflow to run during
low stage operation. (default = 70%)
HtF
Heat Pump Indoor Airflow Trim (default = 0%)
HtH
High Heating Airflow Trim for Inverter Units. See inverter manual for
menu options and defaults
HtI
Intermediate Heating Airflow Trim for Inverter Units. See inverter
manual for menu options and defaults
HtL
Low Heating Airflow Trim for Inverter Units. See inverter manual for
menu options and defaults
LF
View 6 most recent fault codes and clear all fault codes if desired.
(furnace)
Ln
Restart communications between the indoor and outdoor unit.
D
Select the number of stages for the non-communicating outdoor
unit. Default = OFF meaning no outdoor unit.
PPd
Enable Pump Down Mode
Fd
Resets furnace settings to factory defaults.
Ct
Maximum Current Option (system will limit capacity to percentage
of maximum current) (default = 100%)
Control Shared Data Revision Number
t
Resets all outdoor unit settings to factory defaults.
t
System Verification Test (inverters only)
tn
Indoor Airflow for non-communicating outdoor units. (values based
on 400CFM per ton) (default = 3.0 Ton)
t
Select Outdoor Unit Elevation (SL=same level, OL = outdoor lower,
IL = indoor lower) Default = Outdoor Lower
CF
1 = system will try to satisfy the thermostat quickly.
5 (default) = system will try to satisfy the thermostat more slowly.
tgt
Menu is enabled if the
CF
menu is set to 6. Select the target time
the system will attempt to satisfy the thermostat.
UP
Menu is enabled if the
CF
menu is set to 6. Select the percentage
past the target time when the system will transition to gas furnace
operation during heat mode.
tt
Menu is enabled if the
CF
is set to 6. (the gas furnace will run
during the next heat call if the heat pump fails to satisfy the
custom target time for this number of consecutive cycles) (default
= 20 cycles)
Utt
Menu is enabled if the
CF
menu is set to 6. (if low stage gas heat
is able to consecutively satisfy the thermostat under the set target
time for this number of cycles, the system will transition to the
heat pump for primary heating)
dP
Menu is enabled if the
CF
menu is set to 6. (this percentage will
help determine when switching back to heat pump operation is
appropriate. Default = 20%. If target time = 20 minutes, low stage
furnace operation must satisfy the thermostat by less than 16
minutes. (target time - 20% default = 16 minutes).
LED
Display
Menu Description
A
Aux (condensate switch enabled)
t
Enable or disable inverter boost operation. (compressor speed may
increase when this feature is on) (inverter only)
tt
Boost mode will operate above this selected temperature. On = boost
mode always on (default = 105°F) (inverter only)
CAP
Cooling Airflow Profile setting (default = profile D shown as 4)
CP
Heat Pump compressor lockout temperature. Furnace will act as
primary heat source below this temperature. (Default = 45°F)
CdL
Compressor off delay at the beginning and end of a defrost cycle.
(default = 30 seconds)
CFd
Cooling Airflow Off Delay Time. (default = 60 seconds)
CL
Resets all cooling settings to a factory default
Cnd
Cooling Airflow On Delay Time (default = 5 seconds)
C
Control Firmware Revision Number
C
Enable or disable inverter charge mode
CP
Select the range that includes the desired compressor RPS for inverter
cooling operation. See inverter manual for menu options
C
Maximum Compressor RPS for cooling mode (inverter only)
Ct
Percentage of high stage cooling airflow to run during low stage
operation (default = 70%)
CtF
Cooling Airflow Trim (default 0%)
CtH
High Cooling Airflow Trim for inverter units. See inverter manual for menu
options and defaults
Ct1
Intermediate Cooling Airflow Trim for inverter units. See inverter manual
for menu options and defaults
CtL
Low Cooling Airflow Trim for inverter units. See inverter manual for menu
options and defaults
dF
Compressor run time between defrost cycles. (default = 30 minutes) (2
stage units)
dH
Enables or disables dehumidification feature in the outdoor unit (default
= Enabled)
dHL
Select "1" to enable dehumidification when the thermostat DH terminal
is energized. Select "0" to enable dehumidification when the thermostat
DH terminal is de-energized (default = 1)
FCL
View 6 most recent fault codes and Clear Fault Codes if desired (outdoor
communicating units)
FdF
Force system into a defrost cycle (inverter units)
Fd
Constant Fan Speed as percent of maximum airflow (Default = 25%)
Fd
Gas Heat Fan Off Delay (default = 90 seconds)
nd
Gas Heat Fan On Delay (default = 30 seconds)
t
Percentage of high stage gas heating airflow to run during low stage gas
heat operation (default = 70%)
gH
Gas Heat
TROUBLESHOOTING