background image

P

RODUCT

 S

PECIFICATIONS

SS-GPCC

www.goodmanmfg.com

4/09

Supersedes 6/08

P

ACKAGED

 A

IR

 C

ONDITIONER

The PCC Commercial packaged air conditioner 
features combination electric heat/electric cooling 
with dual high-effi

  ciency scroll compressors. This unit 

contains totally enclosed, permanently lubricated 
outdoor fan motors and is designed for over/under or 
downfl ow applications.

Standard Features

• Dual 

high-effi

  ciency scroll compressors with internal 

motor protection for 2-stage cooling

•  Totally enclosed, permanently lubricated outdoor fan 

motors

•  Enhanced copper tube/aluminum fi n coils

•  Fully charged R-22 systems

•  Belt-driven, variable-pitch sheave permits multi-

speed adjustment

•  Expansion valve evaporator coil

•  Time delay for compressors sequence

•  Compressor grommets for vibration isolation

•  Two independent condenser coils for two-stage operation

•  High- and low-pressure controls on all systems

•  Mild ambient switch

•  Centrifugal fan for quiet and effi

  cient operation

Cabinet Features

•  Heavy-gauge, zinc-coated steel cabinet with weather-

resistant powder-paint fi nish

•  Fully insulated with blankets of insulation

•  Vertical discharge with removable grilles

•  Control box and compressors easily accessible from 

side access panels

•  Base rails with fork slots for convenience 

of handling and added rigidity

•  Galvanized steel, powder-coated drain pan with ¾” NPT 

condensate connection

•  Factory wiring conveniently arranged to install accessories

•  Filters are provided with unit (2” disposable)

•  When properly anchored, meets the 2001 Florida 

Building Code unit integrity requirements for 
hurricane-type winds

PCC C

OMMERCIAL

C

OOLING

 C

APACITY

86,000 - 116,000 BTU/

H

10.3 EER

*  Full warranty details available at www.goodmanmfg.com.

7½ 

TO

 10 T

ON

Summary of Contents for 10.3 EER

Page 1: ...grommets for vibration isolation Two independent condenser coils for two stage operation High and low pressure controls on all systems Mild ambient switch Centrifugal fan for quiet and efficient opera...

Page 2: ...s liquid temperature or pressure decreases Caution If control is used below 50 F accumulators should be added to the equipment to avoid slugging of the compressors ROOF CURB PGC 5 Full perimeter curb...

Page 3: ...Fan Diameter 24 24 24 24 Outdoor Nominal CFM 5 500 5 500 6 400 6 400 Face Area ft 15 6 15 6 23 8 23 8 Rows Deep Fins per Inch 2 21 2 21 2 21 2 21 Tube Diameter Material Copper Copper Copper Copper El...

Page 4: ...4 www goodmanmfg com SS GPCC PRODUCT SPECIFICATIONS DIMENSIONS Unit Size A Height B Supply Air C Return Air PCC090 X 36 12 176 16 PCC120 X 52 20 2513 16 X Electrical Designation...

Page 5: ...l A B PCC090 X 6 7 PCC120 X 22 23 X Electrical Designation DIMENSIONS ELECTRICAL CONNECTIONS 1 Main power entrance location 2 Control wiring entrance location 3 Optional field installed internal disco...

Page 6: ...8 4 90 6 68 2 8 4 90 6 81 8 8 4 93 5 93 5 70 WB 8 4 96 4 44 8 8 4 96 4 58 5 8 4 96 4 73 1 8 4 96 4 87 7 73 WB 8 5 101 3 35 1 8 5 101 3 49 7 8 5 101 3 64 3 8 6 101 3 78 9 100 61 WB 8 5 78 9 70 1 8 6 8...

Page 7: ...9 11 7 126 6 126 6 64 WB 11 6 115 9 84 9 11 6 115 9 105 1 11 6 119 9 119 9 11 7 126 6 126 6 67 WB 11 7 122 6 72 7 11 7 122 6 93 0 11 7 122 6 111 8 11 7 126 6 126 6 70 WB 11 8 130 7 60 6 11 8 130 7 80...

Page 8: ...RISE HEAT KIT AVAILABILITY Unit Size HKCB20 HKCB30 HKCB40 7 X X X 10 X X X X Heat Kit Available N A Heater Not Available Notes Maximum air temperature rise of 40 must not be exceeded See table for El...

Page 9: ...SS GPCC www goodmanmfg com 9 PRODUCT SPECIFICATIONS FAN PERFORMANCE DATA...

Page 10: ...MER HEATER ACCESSORIES SEE HEATER W C GY GRAY BK 5 2 ELECTRIC START ELECTRIC W1 HIGH 230 TERMINAL TO 208 TERMINAL MODEL E COMP VT VIOLET FAN RELAY SWITCH WH WHITE Y COOLING TAP MED LOW HIGH HIGH HIGH...

Page 11: ...ER MED PHCB05C1 RELAY GN CAP RELAY COM L1 HORIZ LOW VOLTAGE C ACCESSORY INSTALLATION INSTRUCTIONS OR ORANGE TAP HEAT 1 LOW 22303201 REV 1 230 VOLT 4 FUSE 208 VOLT INSTALLATION LEADS MAY BE USED WITH E...

Page 12: ...LATION BLOWER ACB L1 208 230 VAC 1 FOR PROPER OPERATION ON 208 VOLT THE FOLLOWING CHANGE MUST BE MADE 208 VOLT INSTALLATION MOVE RD6 WIRE FROM TRANSFORMER 230 TERMINAL TO 208 TERMINAL VT 20 RD 10 CONT...