Installation
13
.
.
.
Electrical connection
Warning: you need to connect the two
conductors of the supply cable to a
connection block in respecting the
polarities as following :
IMPORTANT: The wires in the mains
lead are coloured in accordance with
the following code :
Blue – Neutral
Brown – Live
• The blue wire must be connected to the terminal
marked with an N or coloured black.
• The brown wire must be connected to the
terminal marked with an L or coloured red.
WARNING: Never connect live or
neutral wires to the earth terminal.
• This product is double insulated and must not be
earthed. If there are any incoming earth cables,
they must be joined together using a suitable
connector (not supplied) and well insulated with
good quality insulation tape. This is to ensure
earth continuity throughout your property.
Flex outlet method - metal frontplates
Connect the cables as shown in the diagram:
From supply:
Neutral
Live
Earth
To appliance: Live
Neutral
ALL EARTH WIRES MUST BE SLEEVED AND
TERMINATED TO BACK BOX.
• DO NOT wire/fit a plug to this appliance. The
appliance must be electrically connected to a
fused fixed spur, which is fitted with a 7 Amp
fuse for SOLNA35, and with a 10Amp fuse for
SOLNA50 and SOLNA75.
• All fittings must be installed by a competent
person in accordance with the current IET
Wiring Regulations (BS7671). If in doubt, consult
a qualified electrician.
• This product is suitable for use in living areas,
and Bathroom (dry) outside Zones and zone
2 only (see diagram below and current IET
Wiring Regulations for details). It is not suitable
for Bathroom Zones 0 and 1. If being fitted in
a bathroom a 30mA RCD must be used. This
appliance does not come fitted/supplied with a
fused plug.
• Always refer to the Reference Drawing for
Bathroom Installation.
Note
: the below drawing is for reference only.
(DRY) OUTSIDE ZONES
ZONES 0
ZONES 2
ZONES 1
2.25 m
0.6 m
0.6 m
ZONES 2
Window
recess
Ceiling
IP24: THIS PRODUCT IS SUITABLE FOR
BATHROOMS (DRY) OUTSIDE ZONES AND
ZONE 2.
• Full details can be found in the current IET
Wiring Regulations (BS7671).
L
N
L
N
E
E
Summary of Contents for Solna 3663602438229
Page 9: ...Installation 09 1 2 Max 250 mm 03 04 02 1 2 Max 250 mm...
Page 11: ...Installation 11 03 04...
Page 12: ...Installation 12 05 1 1 2 06 1 2 2...
Page 42: ...Installation 42 1 2 Max 250 mm 03 04 02 1 2 Max 250 mm...
Page 44: ...Installation 44 03 04...
Page 45: ...Installation 45 05 1 1 2 06 1 2 2...
Page 75: ...1 2 Max 250 mm 03 04 02 1 2 Max 250 mm Monta 75...
Page 77: ...03 04 Monta 77...
Page 78: ...05 1 1 2 06 1 2 2 Monta 78...
Page 106: ...1 2 Max 250 mm 03 04 02 1 2 Max 250 mm Instalare 106...
Page 108: ...03 04 Instalare 108...
Page 109: ...05 1 1 2 06 1 2 2 Instalare 109...