Good Earth Lighting UC1304-WH1-12LFW-G Quick Start Manual Download Page 1

Required/ Nécessaire/ Obligatorio

Hardware kit* / Trousse de quincaillerie* / 

Kit de aditamentos*

WARNINGS AND CAUTIONS

INSTALLATION

READ ENTIRE INSTALLATION PROCEDURE BEFORE 

YOU BEGIN!
THIS FIXTURE IS DIMMABLE USING THE GOOD 

EARTH LIGHTING APP.

(INSTRUCTION SHEETS INCLUDED)

If unsure if the electrical box is properly grounded, or the box is plastic 

and has no ground wire, or are unfamiliar with the methods of properly 

grounding fixture, consult a qualified electrician. 

1.  Do not look directly at exposed LEDs for extended period of time.

2.  LEDs gradually emit less light over their lifetime.

3.  Do not use in wet locations. 

FOR INDOOR USE ONLY. 

4.  Do 

NOT

 mount to surfaces less than ¼ in.

5.  For electrical requirements, see fixture. Minimum 90°C supply conductors.

6.  Do 

NOT

 mount over sinks or stoves. 

7.  Do 

NOT 

install these lights inside of enclosed cabinets. 

8.  Turn power off before servicing. 

9.  Do not leave bare wires exposed. 

10. Not intended for recessed installation in ceiling or soffits. 
11. Maximum number of fixtures per run must not exceed maximum power supply  

 

    wattage rating of 360 W. (10 fixtures total) 

 LED UNDER CABINET  BAR 

(Page 1)

RAMPE D’ÉCLAIRAGE À DEL À INSTALLER SOUS UNE ARMOIRE

 (Page 3)

BARRA CON LUZ LED PARA DEBAJO DEL GABINETE 

 (Página 5)

Model / Model / Modelo # UC1304-WH1-12LFW-G , UC1304-WH1-18LFW-G , 

UC1304-WH1-24LFW-G , UC1304-WH1-30LFW-G 

Diffuser    

Diffuseur   

Difusor

* Actual hardware may differ from illustration.

* La quincaillerie incluse peut être différente de l’illustration. 

* Los aditamentos reales pueden diferir de los que se muestran en la ilustración.

ON/OFF Rocker Switch

Interrupteur à bascule

Interruptor oscilante

de encendido/apagado

Pre-installed Captive Screws

Vis captives installées préalablement 

Tornillos cautivos preinstalados

Access Cover

Couvercle pour l’accèsr

Cubierta de acceso

Plastic screw cover

Caches des vis 

Cubiertas de tornillo 

IMPORTANT SAFETY INFORMATION

WARNING: SHUT OFF POWER AT THE CIRCUIT BREAKER OR FUSE PANEL BEFORE REMOVING THE OLD 

FIXTURE OR INSTALLING A NEW ONE.

3

2

1

CCx1

OPTION A

OPTION B

2B

BBx1

CCx2

BBx2

Remove the access cover by loosening the locking screw and slide the keyhole slot over the screw head, until it reaches to the large end of the 

keyhole slot. As the access cover is removed from the fixture, the ends of the wires/wire connectors will be pulled out with it. Carefully, pull the ends 

out about 3 inches and clip the zip tie that is attaching them to the access door.  
Determine which corresponding knock-out is closest to the supply wire feed and remove it. 

CAREFULLY REMOVE THE KNOCK-OUT BY 

HAMMERING A FLAT HEAD SCREWDRIVER OR PUNCH UNTIL THE SURFACE BREAKS.

 If the knock-out did not break free, use pliers (not 

included) and bend it back and forth until it snaps off.

Option A (NM Cable): 

Attach the round plastic strain relief 

(CC)

 by pushing the wedge base into the knock-out hole until it locks into position. Push 

the NM cable through the strain relief, allowing enough wire length to make the connections.  

Option B (Flexible Whip): 

 Attach the metal strain relief 

(BB)

 to the end of the flexible whip and turn until the strain relief 

(BB)

 is fully engaged with 

the end of the cable. Push the strain relief 

(BB)

 and cable into the knock out and lock into position (allow enough wire length to make the connection). 

Fixture must be properly grounded. Insert ground supply lead into connector on ground fixture wires.The ground wires can be either green or bare 

copper. Insert black supply lead into connector on black fixture wires and white supply lead into connector on white wires. 
Push excess wire into the wire compartment. Re-attach the access cover by sliding the access cover away from the screw head until the screw head 

is captured by the narrow end of the keyhole slot. Tighten the locking screw back down.

1

2

3

4

2A

2B

TURN POWER OFF AT BREAKER BOX/FUSE BOX. TURN WALL SWITCH TO JUNCTION BOX OFF

AAx2

Linking cord

Cordon de raccordement

Cable de enlace

2A

Optional Wiring method:

  

To pass through wiring with power 

feeding back out to the next fixture the following is provided. For NM 

cable or Flexible whip, use a second strain relief and the second KO 

in the access cover. Push the second set of wires into the 

corresponding quick connect with black to black, white to white and 

ground to ground.

OPTIONAL WIRING METHOD

4

Pairing Button

Bouton d’appariement

Botón de emparejamiento