Retire la cadena de soporte. Inserte la cabeza del primer tornillo en la ranura

con forma de cerradura recta        , gire la lámpara y pase el segundo tornillo

en la ranura con forma de cerradura curvo        . Una vez que los tornillos

estén instalados, coloque la lámpara en la posición deseada. Apriete

los tornillos.

2

2

Distributed by:

 Good Earth Lighting

®

 

1400 East Business Center Drive, Ste. 108  Mount Prospect, IL 60056

Fixture doesn’t light.

Problem

Cause

Solution

Fuse blows or circuit breaker trips

when light is turned on.

Power is off.

Bad connection.

Bad switch.
Discontinue use.

Check if power supply is on.

Check cords and/or wiring.

Test or replace switch.
Call Customer Service Center

1-800-291-8838.

Before doing any work on the fixture, shut off power supply at the circuit breaker panel

to avoid electrical shock.

Hardware Kit:

ZH-UC1061F00-WH1
Replacement Diffuser:

ZD-UC1061L12-FST

ZD-UC1061L18-FST

ZD-UC1061L24-FST

ZD-UC1061L30-FST

Replacement Parts List

SAVE THESE INSTRUCTIONS.

Troubleshooting Guide

Printed in China

Care and Maintenance

Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner and soft cloth. When cleaning the fixture, make sure the power is turned off. Do not spray cleaner 

directly onto any part of the fixture of LEDs. 

6 YEAR LIMITED WARRANTY

The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of (6) years from the date of original purchase by the consumer. 

The fixture is not warrantied for use in a commercial or retail application.  The warranty is limited to use in a residential environment. We will repair or replace (at our option) the 

unit in the original color and style if available, or in a similar color and style if the original item has been discontinued, without charge. Defective units must be properly packed and 

returned to the manufacturer with a letter of explanation and your original purchase receipt showing date of purchase. Call 

1-800-291-8838

 to obtain a return authorization number 

and an address where to ship your defective product. Note: C.O.D. shipments will NOT be accepted. The liability of the manufacturer is in any case limited to replacement of the 

defective light fixture product. The manufacturer will not be liable for any other loss, damage, labor costs or injury which is caused by the product. This limitation upon the liability 

of the manufacturer includes any loss, damage, labor costs or injury which is (I) to person or property or otherwise; (II) incidental or consequential in nature; (III) based upon 

theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale, use, or repair of the product. This warranty gives you 

specific rights, and you may also have other rights which vary from state to state.

FCC Statement

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 

interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could 

void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits 

are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and 

used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this 

equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by 

one or more of the following measures: 1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit 

different from that of the receiver. 4) Consult the dealer or an experienced radio/TV technician for help.

1

1

2

2

3

4

5

6

7

8

3

7

6

4

8

Disconnect power to the electrical box and remove the old fixture. If more than two wire leads are present, keep track of which wires were connected together. Remove the 

diffuser by pulling back and up on the top edge. To open the wire compartment cover, disengage both chassis locking tabs by pushing in the side of wire compartment cover and lifting it 

up to expose the wire connections and hardware kit inside. 
Mark the general area to install the fixture. Locate the mounting keyhole slots on the back of the fixture. Mark the corresponding placement on the mounting surface. Use an awl or nail to 

dimple the screw holes or drill a 1/16 in. pilot hole into the marked locations. Tighten the screws leaving 1/2 in. of the screw protruding from the surface. Determine which corresponding 

knock-out is closest to the supply wire feed and remove it. CAREFULLY REMOVE THE KNOCK-OUT BY HAMMERING IT WITH A FLATHEAD SCREWDRIVER OR PUNCH UNTIL THE SURFACE 

BREAKS. If the knock-out does not break free, use pliers and bend it back and forth until it snaps off. 

Attach the strain relief by inserting the threaded end through the knock-out. Secure the strain relief to the fixture by tightening the fastener to the threaded tube. 

NOTE

: Remember to have 

the strain relief screws oriented in a manner that allows tightening/loosening of the clamp after the fixture has been attached to the mounting surface. 
Insert a flexible whip or NM cable (not included) through the strain relief and tighten the clamp until it is secure. Allow enough wire length to make the connection. 

WARNING: 

Make sure 

power is turned off.  

Fixture must be properly grounded. Connect fixture ground wire to ground wire. 

Connect the supply leads to the fixture wire leads using the supplied wire nuts. The black leads 

from the fixture go to the black supply lead and the white leads from the fixture go to the white supply lead. Tighten the wire nuts properly to prevent the wires from coming loose. If 

unsure of tightness, tape the wire nuts to the wire using electrical tape. Carefully push any excess wiring back inside the fixture.
Re-attach the wire compartment cover by hinging the cover with the fixture chassis and closing. Press on the cover and secure the front lip under the locking tab. 

Slide the fixture over until the narrow ends of the keyhole slots are under the heads of the wood screws. Finish tightening the wood screws until they are firmly seated and the fixture is 

tightly secured to the mounting surface.
Re-install the diffuser 

5

DD

DD

English

Model / Modèle / Modelo #: LF1086-BR4-32LF2-G

32 in. Portal LED Flush Mount Ceiling Fixture

 

(Page 2)

Plafonnier encastré à DEL Portal de 81,28 cm

 

(Page 3)

Lámpara LED de techo de instalación al ras Portal de 81,28 cm

 

(Página 4)

English

GND

CC

x1

EE

x1

AA

x4

BB

x2

DD

x2

FF

x1

*Actual hardware may differ from illustration

* La quincaillerie incluse peut être différente de l’illustration.

*Los aditamentos reales pueden diferir de los que se muestran en la ilustración.

Hardware kit / Trousse de quincaillerie/ Kit de aditamentos

Required / Nécessaire/ Obligatorio

Diffuser

Diffuseur

Difusor

Fixture Pan

Support du luminaire

Bandeja de la lámpara

Locking Tab

Languette de verrouillage 

Lengüeta de empalme 

English 

Warnings and Cautions (Page 1)

Fixture Installation (Page 2)

Replacement Parts List  (Page2)

Troubleshooting Guide (Page 5)

Good Earth Lighting

® 

Warranty (Page 6)

 

Reviews: