GONSIN DCS-3021 User Manual Download Page 1

DCS-3021 Conference System

User Manual

Summary of Contents for DCS-3021

Page 1: ...DCS 3021 Conference System User Manual...

Page 2: ...ndicators 13 3 2 Functions and Indicators of Wireless AP 14 3 2 1 Basic Functions 14 3 2 2 Indicators 14 3 2 3 WAP 30 15 3 3 Functions and Indicators of Charging Case 15 3 3 1 Basic Functions 15 3 3 2...

Page 3: ...02 DCS 3021 Congress System Chapter 8 FAQs Appendix 25 24...

Page 4: ...ent Select proper package or original card serves as a basis for future maintenance package for transportation free of charge 9 Keep the equipment room ventilated so as to prolong the service life of...

Page 5: ...attery may be damaged resulting in fire or explosion Do not set the battery in water or moisten the battery anode cathode otherwise the battery will be corroded and heated up resulting in leakage fire...

Page 6: ...tenance does not need much skill as well technicians can operate the terminal after a short period of training System composition The DCS congress system is composed of the congress server wireless co...

Page 7: ...10mm Pluggable Microphone Stem Black MIC 410 14 5 Y 410mm Pluggable Microphone Stem Black MIC 510 14 5 Y 510mm Pluggable Microphone Stem Black MIC 310 14 5 Y 310mm Pluggable Microphone Stem Silver MIC...

Page 8: ...Functions and Indicators 2 2 1 Basic Functions 1 Use 2 4GHz frequency hopping technology to automatically detect 2 4GHz RF resources and use reliable frequency hopping mechanism to avoid co channel in...

Page 9: ...ne channel 6P interface This interface is used for connecting to WAP 30I for increasing the 3 Operation buttons up down left right arrow buttons number of listening units and simultaneous 4 OK button...

Page 10: ...nector connects the male connector of 8P2 01 male male connector cable the other male connector of 8P2 01 connects to the female connector of WAP 30 AP as shown in the following figure 2 4 2 Connectio...

Page 11: ...ng to the congress server power of the camera is supplied directly from the control room One group is the HD video wiring which is implemented by connecting the video output of the dome camera to the...

Page 12: ...er to 485 and 485 of central control unit Please note that the RS485 control cable of dome camera is already connected with RS485 control cable of central control unit The control cable of dome contro...

Page 13: ...Within a building set different host IDs for multiple wireless congress systems to avoid mutual interference 2 Frequency sweep enter the Frequency sweep interface and select Yes to conduct frequency 5...

Page 14: ...s terminal Function description host ID is a code used within a system for internal communication Communication can be successful only when the host ID of the system is consistent with that of a congr...

Page 15: ...The system is recommended to use in the medium or small conference room 14 Product model WAP 30 3 2 1 Basic Functions 1 RUN indicator 2 Powered by the congress server 3 Wall mounting bracket supporti...

Page 16: ...owered by the universal power supply and automatically matched by the voltage of the city power Each charging grid has a charging indicator light The charging circuit can automatically detect the batt...

Page 17: ...nect the 8P interface female connector of the server to a WAP 30 AP with one male connector of the cable connected to the congress server and the other female connector connects the male connector of...

Page 18: ...frequency band 2 4000 2 4835 GHz 4 3 2 Wireless PC Network The wireless PC network is based on 2 4GHz wireless communication technology as well and there are 13 channels available on the PC network R...

Page 19: ...nt kinds of materials Minor impact glass wood gypsum asbesto Major impact water brick stone Completely block marble cement concrete metal The following instructions should be followed when you are ins...

Page 20: ...ng apart from room A Situation 1 Room A B C on the same floor or neighboring floor because they are very near each other RF PARM Host ID and broadcast channel shall be DIFFERENT Room A RF PARM FIX 1 H...

Page 21: ...Channel 1 Fix2 Fix3 or Fix 1 Channel 6 Fix3 or Fix1 Fix2 Channel 11 the HOST ID and broadcast channel of DCS3021 shall be different The other 2 4GHz wifi devices can reserve one channel to work in thi...

Page 22: ...h 1 5m 5 1 2 8PS 03 05 10 15 20 40 Extension Cable Item Color Black Type 8PS Connector Male connector x 1 female connector x 1 Length 5 types namely 3m 5m 10m 15m 20m Description 5 1 3 UTP Five Catego...

Page 23: ...dB signal to noise ratio based on A weight LINE OUT 20dBu AV110 220V 10 50 60Hz 19inch standard rack 1U rack 340mm 420mm 45mm 4KG 0 45 C 20 50 C RS 485 AUTO FIFO 1 2 3 1 PELCO P 9600 VISCA 1 RS 232 1...

Page 24: ...gistration Operating temperature Storage temperature Sound pickup distance Built in loudspeaker Product Name Item 2 4GHz frequency hopping 30Hz 16KHz 7 5dB 46dB 1dB 3 7V 2600mAH lithium ion battery DC...

Page 25: ...e Power Charging duration Weight Dimensions Operating temperature Storage temperature Product Name Item Charging case Parameter AC100 240V 50 60Hz 4 2V 106W 3 5h 6 7 kg net weight 7 4 kg fully loaded...

Page 26: ...a risk of fire or other damage 6 Do not dismantle the housing of the congress terminals otherwise the product poses a risk of electric shock To maintain the devices contact GONSIN after sales service...

Page 27: ...her the and of the RS 485 cable is reversely connected and whether the copper core of the binding post is inserted into the RS 484 interface of the central control unit and locked Check the ID and pro...

Page 28: ...to product upgrade or change of product appearance and specification information in this document is subject to change without notice GONSIN reserves the right of final interpretation Before use pleas...

Page 29: ...DCS 3021 Congress System 27...

Page 30: ...GONSIN Conference Equipment Co Ltd...

Reviews: