Installation and Instruction Manual

Inverter Air Source Heat Pump

Gondzik Home Technologies GmbH

Sterkrader Strasse 49-59 Turm 9

13507 Berlin-Deutschland

Tel.

030/31170795

Summary of Contents for Delta 13

Page 1: ...Installation and Instruction Manual Inverter Air Source Heat Pump Gondzik Home Technologies GmbH Sterkrader Strasse 49 59 Turm 9 13507 Berlin Deutschland Tel 030 31170795...

Page 2: ......

Page 3: ...heat pump 2 The data of unit 5 6 9 10 10 11 11 12 12 13 27 30 30 11 1 Application of heat pump 2 Choose a right heat pump unit 3 Installation place 4 Installation method 5 Water loop connection 6 Pow...

Page 4: ...uded which is very easy for installation 3 Flexible installation The unit has smart structure with compact body just simple outdoor installation is needed This series of heat pump unit owns following...

Page 5: ...n Compulsory implement The listed action need to be taken ATTENTION include WARNING Please pay attention to what is indicated Mark Notes Icon notes WARNING ATTENTION To prevent the users and others fr...

Page 6: ...ff to stop the unit Continue to run may cause electrical short or fire Move and repair Entrust Prohibit Entrust When the heat pump need to be moved or installed again please entrust dealer or qualifie...

Page 7: ...check the installation basement in a period one month to avoid any decline or damage on the basement which may hurt people or damage the unit Safety Precaution Meaning Fix the unit Installation Place...

Page 8: ...te Controller Manually Water outlet tube The longest distance of installing the remote controller is 200 meters Water intlet tube Remote Controller Manually Water outlet tube Air outlet in horizontal...

Page 9: ...antity Fan Power Input Fan Rotate Speed Water Pump Input Noise Noise Range Water Connection Water Flow Volume External Pressure Unit Net Dimensions L W H Unit Shipping Dimensions L W H Net Weight Ship...

Page 10: ...cification Models Delta 9 442 490 Water inlet 1 Water outlet 1 805 750 1002 392 332 155 65 915 423 460 700 953 Water inlet 1 Water outlet 1 357 85 706 128 Models Delta 13 Power line Signal line Drain...

Page 11: ...8 3 Unit dimension Specification Models Delta 20 997 650 395 437 1315 Water inlet 1 1 4 Water outlet 1 1 4 125 55 1030 Power line Signal line...

Page 12: ...lter Plate heat exchanger Buffer tank Expansion tank 10 11 12 13 14 15 16 17 18 19 20 21 T T 3 4 3 4 6 5 5 5 5 5 8 9 5 5 12 16 2 2 5 1 Buffer tank Hot water tank 15 14 21 18 17 5 5 5 19 13 5 5 7 20 10...

Page 13: ...oling unit for cooling chilled water outlet temp at 5 15 maximum ambient temp at 43 For heating warm water inlet temp at 40 50 minimum ambient temp at 25 Unit application a s w h p is used for house o...

Page 14: ...ank on the top point of the water loop and the water level in the tank must be at least 0 5 meter higher than the top point of the water loop 6 Power supply connection Open the front panel and open th...

Page 15: ...ller Check whether the water pump is running if it runs normally there will be 0 2 MPa on the water pressure meter When the water pump runs for 1 minutes the compressor will start Hear whether there i...

Page 16: ...Operation and Use 1 Main interface display and function 1 Power on interface 2 Starting up interface 13 13 11 12...

Page 17: ...this key Note is fault icon This Icon will flash when there is an error shown up then the display will enter Failure record interface after tapping this icon is ambient temperature icon show the curre...

Page 18: ...n and off 1 In shutting down interface on off key is in gray status press on off key can start up the machine 2 Note In starting up interface on off key is in red status press on off key can shut down...

Page 19: ...n on the interface 4 tapping hot water heating mode icon then the display will go into hot water heating mode interface 5 tapping hot water cooling mode icon then the display will come to hot water co...

Page 20: ...key to undo the last action Note means the new target temp under current setting Tapping this key can save you action and back to the main interface 1 4 When the target temp is being set pop up keybo...

Page 21: ...n and Use Note Input the password of 22 or 022 click the enter key and the screen will be unlocked 1 6 Timer setting Click the timer setting key to enter the timer setting and the interface display is...

Page 22: ...inute of timer on Minute of Timer on is shown Hour of Timer on is shown Enable the timer off Enable the timer on Click this key to start or turn off the timed start up function Click this key to start...

Page 23: ...Operating mode Click the key and enter the password to enter the factory parameter settings and status parameters interface Click this key to set the system time In the setup interface 1 Tapping opera...

Page 24: ...ey to cancel the current settings and return to the settings page Click this key to save the current settings Enter key Up key Down key Click the up and dowm key to set the month Click the up and dowm...

Page 25: ...the icon is displayed as While the unit is in cooling mode clicking the icon the electric heating will not be turned on While the unit is in hot water cooling mode if the hot water side is running th...

Page 26: ...s displayed as 4 1 Tapping Mute Timer button then the interface display is shown as follows 23 Note Click to set the day of the week click to active the mute mode then click to select the morning or a...

Page 27: ...me point The leftmost point on the first page 0 on the abscissa is the latest temperature record 5 Temperature curve record is provided with power down memory function Operation and Use 24 1 7 Fault i...

Page 28: ...act 1 Motor is in locked rotor state 2 The wire connection between DC fan motor module and fan motor is in bad contact 1 Change a new fan motor 2 Check the wire connection and make sure they are in go...

Page 29: ...e IPM sampling electricity is fault Frequency conversion board and main board communication failure Sensor Fault of Module Radiator IGBT Power Device Overheat Alarm F20 Overload Alarm EEPROM Fault Ala...

Page 30: ...Use 3 Interface diagram V R T A B G Sign Meaning V R T A B G 3 1 Wire control interface diagram and definition 12V power No use No use 485A 485B GND power 3 2 Controller interface diagram and definit...

Page 31: ...No use No use No use System Exhaust temperature 1 Water flow switch protection The low preesure switch 1 The high preesure switch 1 Temperature Water tank Temperature System1 Antifreeze 1 Temperature...

Page 32: ...4 GND 3AI 10 50K 2 GND 1AI 9 50K 1 2 3 4 5 4 3 2 1 5 4 3 2 1 System 2 fan coil temperature System 2 suction temperature System 2 pressure sensor System 2 compressor current detection System 2 Exhaust...

Page 33: ...life must be handled separately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Direc...

Page 34: ...ase line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 1...