golmar CD-PLUS/90 Instruction Manual Download Page 1

CD-PLUS/90

Protocol

converter

Instructions manual

TCD-PLUS/90ML 

rev.0112

Cód. 50121600

Summary of Contents for CD-PLUS/90

Page 1: ...CD PLUS 90 Protocol converter Instructions manual TCD PLUS 90ML rev 0112 C d 50121600...

Page 2: ...o connection with Coaxial cable O Connection block to Plus system video connection with Coaxial cable O EL564 transceiver to convert video signal from twisted pair to coaxial and from coaxial to twist...

Page 3: ...be connected to the 90 system through the protocol converter CD Plus 90 There is an option to place a CE 990 Plus porter s exchange between the converter and the Plus door panel Installation diagrams...

Page 4: ...be firmly fixed DIN 46277 To install the converter directly on the wall drill two holes of 6mm and insert the wallplugs Fix the converter with the specified screws escription of the converter D DIN ra...

Page 5: ...e Plus system through distributors or only in the last converter if the connection to the Plus system of the converters does not contain distributors input output mode Factory default To reset the con...

Page 6: ...converter programming by setting dip switch number 1 to ON The door panel will emit a tone and the green LED on the converter will begin to blink slowly indicating that programming has begun To indica...

Page 7: ...e M Plus door panel For other configurations of replacement contact with your distributor M T 840 T 790VD T 840 _ SA _ SA T 790VD HZ _ HZ _ Next Distributor SW2 SW2 SW2 SW1 D Malla Vin Ain Aout Vin Vo...

Page 8: ...figuring the end of line in the last monitor Cut the resistor in all distributors except in the last one For other configurations of replacement contact with your distributor 230 110 0 SEC PRI FA PLUS...

Page 9: ...TP Out Coax In Mp1Malla Vin 2C Vpo Mpo Vpi Mpi Md1 Vd1 Md2 Vd2 _ _ _ Mp _ VpMp _ TP to Coax Coax to TP EL562 JP1 JP1 JP2 SW2 SW1 D Malla Vin Ain Aout Vin Vout Vout CN2 AP CV1 CV2 12 EL500SE PLUS BUS...

Page 10: ...PRI Main 1 BACKBONE 1 IMPORTANT To configure and to program each equipment see the appropiate instruction book ackbone encoder mode Plus general door panels with coaxial cable B M D Ao Ain Vi CT Vo C...

Page 11: ...BUS 90 BUS JP1 M Vi Vo Malla Malla A 490 1 N R 2 0 220 PRI 1 A 490 2 _ Vin Vout Shiner 90 SA A1 2C 75W _ Vin Vout Platea 90 SA A1 2C D2L 90 E S 75W D1 D2 SW1 BACKBONE 250 M Master S Slave Configuring...

Page 12: ...e the appropiate instruction book M BACKBONE 1 M CV 1 Vout Vin L1 L2 CV CV A 2 1 2 3 SW 4 PV 90 A 490 1 N R 2 0 220 PRI 1 A 490 2 D Ao Ain Vi CT Vo CD PLUS 90 PLUS BUS 90 BUS JP1 Vi Vo Malla Malla S N...

Page 13: ...D2 SW1 BACKBONE 250 Malla Vout CT EL 564 Vp2 Mp2 Malla IN JP1 D Ao Ain Vi CT Vo CD PLUS 90 PLUS BUS 90 BUS JP1 M Vi Vo Malla Malla A 490 1 N R 2 0 220 PRI 1 A 490 2 _ Vin Vout Shiner 90 SA A1 2C 75W...

Page 14: ...220 PRI 1 A 490 2 Next Distributor _ Vin Vout Shiner 90 SA A1 2C 75W _ Vin Vout Platea 90 SA A1 2C D2L 90 E S 75W D1 D2 CN1 SW1 Configuring the end of line in the last monitor distributors except in t...

Page 15: ...Shiner 90 SA A1 2C 100W Platea 90 SA A1 2C D2L 90 2H CN1 SW1 Configuring the end of line in the last monitor Remove the jumpers JP1 JP2 in all distributors except in the last one For other configurat...

Page 16: ...ctions w Check that the voltage between and terminals of the FA Plus C power supply is from 17 5 to 18 5Vd c if not check the power supply and its connections OThe converter cannot be programmed w Che...

Page 17: ...771 215 7550 216 7017 216 7018 Fax 218 5542 Mobil 30 940 1970 30 959 0930 E mail info delton hu Web www delton hu www golmar hu 1141 Budapest Fogarasi t 77 Tel 220 7940 220 7814 220 7959 220 8881 364...

Reviews: