PFS APPROVED FOR NATURAL GAS OR PROPANE GAS

Z21.50 - 2014

If your plans do not allow for the venting system as outlined 

previously in the “installing chimney/vent system” section, you may 

contact ENERVEX, Inc. (formerly EXHAUSTO) at 800-255-2923. 

They will design an approved venting system to suit your venting 

needs. These power vented systems follow the standards and codes 

as outlined under the NFPA 54/ANSI Z223.1 Nation Fuel Gas Code. 

Please check with the local authority having jurisdiction in your area.

The engineers at ENERVEX are familiar with Golden Blount 

fireplaces and their systems will allow you to minimize the amount of 

vent pipe exposed outside of your home. Fireplaces may also be 

horizontally vented with these systems.

10/17

MODELS  LFP4218/LFP6018/LFP

7

218  TOP  VENT  GAS  FIREPLACE

f i r e - p a r t s . c o m

Summary of Contents for LFP4218

Page 1: ...g needs These power vented systems follow the standards and codes as outlined under the NFPA 54 ANSI Z223 1 Nation Fuel Gas Code Please check with the local authority having jurisdiction in your area The engineers at ENERVEX are familiar with Golden Blount fireplaces and their systems will allow you to minimize the amount of vent pipe exposed outside of your home Fireplaces may also be horizontall...

Page 2: ...ing Instructions 14 15 Trouble Shooting 16 17 Replacement Parts 18 2 INSIDE ROOM FLUSH MOUNT CHASE CORNER MOUNT 61 86 5 44 INSTALLATION OPTIONS Figure 2 1 A B C A B C LFP4218TV 61 86 5 44 85 117 5 61 5 LFP6018TV Glass Installation Flame Stabilizer Installation 10 12 Maintenance Instructions Wiring Diagram 13 Operating Guidelines 12 LFP7218TV 89 75 127 72 fire parts com ...

Page 3: ...218 TOP vENT FIREPLACE INTERIOR vIEW Outside Air Control Knob Damper Control Lever Pilot Assy Flame Sensor On Off Switch Outside Air Connection 3 valve Access Door Stand Off Stand Off Burner fire parts com ...

Page 4: ...W Left Outside Air Control Damper Control Lever Pilot Assy Flame Sensor Right Outside Air Control On Off Switch LEFT RIGHT 4 Valve Access Door OUTSIDE AIR CONNECTIONS LFP6018 7218 TOP VENT FIREPLACES fire parts com ...

Page 5: ...NTROL VALVE A SPARK TO PILOT LIGHT ASSEMBLY AND ON OFF ROCKER SWITCH WARNING THIS UNIT IS NOT FOR USE WITH SOLID FUEL NOTE INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPER...

Page 6: ... AT THE CONTROL WITH POSSIBLE FIRE OR EXPLOSION Include a manual shut off valve and union in the line so the control or heater may be disconnected for servicing Include a drip leg and a plugged 1 8 N P T tapping into the line also The tapping must be accessible for the test gauge connection immediately upstream of the gas supply connection to the unit Use a soap and water solution or liquid gas le...

Page 7: ...d to accommodate wall covering and facing material The framing should be constructed of 2 x 4 lumber or heavier The framing headers may rest on the standoffs Refer to Figure 8 1 for and framing reference dimensions CAUTION VERIFY FIREPLACE DIMENSIONS FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING CONSTRUCTION BEGINS Determine the exact position of the so that the vent run can be planned ...

Page 8: ...f the roof opening see below 8 MINIMUM FRAMING DIMENSIONS 52 36 24 31 23 1 2 35 6 7 18 42 51 2 5 6 5 FRONT OF APPLIANCE FRONT VIEW TOP VIEW SIDE VIEW OPENING HEIGHT HOLE FOR GAS LINE UNIT DIMENSIONS FOR CONSTRUCTION PLANNING Figure 8 1 10 1 2 4 MINIMUM FRAMING DIMENSIONS LFP4218 MINIMUM FRAMING DIMENSIONS PRIOR TO POSITIONING UNIT FINISHED FRAMING DIMENSIONS WITH UNIT IN POSITION NOTE DIMENSIONS P...

Page 9: ...d fuel burning appliance Note A draft hood is installed and is in the same atmospheric pressure zone as the combustion air inlet to the appliance and is located so that the relief opening is accessible for checking vent operation 9 Installing Outside Air Kit Models LFP4218 6018 are supplied with the component parts for outside combustion with the exception of the 4 duct It is recommended that the ...

Page 10: ... with 15 lbs of that is used to burner tray and be distributed around the surrounding area of the 2 Fill burner tray with glass even with or slightly above of Figure 9 1 3 Distribute remaining glass around front sides and rear of burner tray covering area Figures 10 2 11 1 STUD 2X4 HEADER FINISHED WALL NON COMBUSTIBLE SEAL JOINT MANTLE 12 MIN TOP OF OPENING Figure 10 1 Figure 10 2 10 GLASS INSTALL...

Page 11: ...E STABILIZER INSTALLATION 1 ALL LFP MODELS ARE SUPPLIED WITH A GLASS FLAME STABILIZER THAT HELPS BURNER 2 LOCATE GLASS FLAME STABILIZER CLIPS AND INSERT GLASS FLAME STABILIZER INTO BOTH CENTER GLASS FLAME STABILIZER SO THAT THERE IS SAME CLEARANCE ON LEFT AND RIGHT SIDES fire parts com ...

Page 12: ... ROOM AS THE APPLIANCE IMPORTANT TURN OFF GAS BEFORE SERVICING APPLIANCE IT IS RECOMMENDED THAT A COMPETENT SERVICE TECHNICIAN PERFORM THESE CHECKUPS AT THE BEGINNING OF EACH HEATING SEASON WARNING THE FLOW OF COMBUSTION AND VENTILATION AIR MUST NOT BE OBSTRUCTED When lit for the time the appliance will emit a slight odor for an hour or two This is due to paint and lubricants used in the manufactu...

Page 13: ...Visually inspect pilot periodically Brush or blow away any dust or linen accumulations If pilot is plugged disassembly may be required to remove any foreign material from or tubing Venting system should be periodically examined by a service technician or agency to ensure proper air 13 WIRING DIAGRAM FLAME SENSOR REMOTE WALL SWITCH CONNECTION fire parts com ...

Page 14: ...as been under water Immediately call a service technician to inspect the appliance and to replace any part of the gas control system which has been under water LIGHTING INSTRUCTIONS ELEC SPARK TO PILOT 1 STOP Read the safety information on page 11 2 Set the switch to OFF 3 Remove batteries from battery pack 4 This appliance is equipped with an ignition device which automatically lights the burner ...

Page 15: ...use a telephone inside of building 3 Shut off gas at L P tank outside of building 4 Telephone gas company and department Ask instructions Before hanging up give your name address and phone number DO NOT go back into building If your L P tank runs out of fuel turn off gas at the appliance After L P tank is appliance must be re lit according to manufacturer s instructions If The gas control has been...

Page 16: ...16 fire parts com ...

Page 17: ...17 fire parts com ...

Page 18: ...TP TV 132 TV 130 LFP 111 LFP 111 6018 LFP 112 LFP 112 6018 TV 124 TV 125 STP TV 129 STP TV 126 Gas Valve N G Gas Valve LP 1 4 Pilot Gas Line 3 8 Burner Gas Line 4218 1 2 Burner Gas Line 6018 15 Fireglass 4218 On Off Switch Pilot Assembly NAT 4218 Pilot Assembly NAT 6018 Pilot Assembly LP 4218 Pilot Assembly LP 6018 Flame Sensor 3 8 Shut Off Valve Burner Orifice NAT 4218 Burner Orifice NAT 6018 Bur...

Page 19: ...19 Inc fire parts com ...