Instruction Manual - Touch Screen
2011, 2848, 2860, 2872, and 2873 (32 oz. Pop-O-Golds)
PopClean Elite Popper -600 Series
2911, 2948, 2960, 2972, and 2973 (52 oz. Medallions)
Page 14
gmpopcorn.com
Fire Suppression System
(some Exports excluded)
Information in this section is intended for reference use by an Ansul Certified Representative ONLY,
for units equipped with a Fire Suppression System (some Exports exclude Fire Suppression System).
The Elite Series PopClean Poppers must be properly installed observing all minimum clearances
(reference Setup section) and have all electrical requirements met prior to the activation of the
Fire Suppression System (reference Electrical Requirements section). If the system is to be
connected to the building alarm, contact a qualified alarm system technician to make the
connection prior to having the Fire Suppression System activated (reference below Connecting
to a Building Alarm System).
The Elite Series Popper is equipped with an ANSUL R-102 Fire Suppression System. All
components are in accordance with the Ansul R-102 specifications and are tested and approved
by Intertek-ETL to U.L. Standard 710B.
The Fire Suppression System is fully assembled and a tank is provided for the liquid fire
suppressant agent, ANSULEX (the tank must be charged with agent by an Ansul Certified
Representative ONLY). The unit will not turn on if the Fire Suppression System is not activated.
As the popper unit is plugged in (when the Fire Suppression System is armed) a distinct click can
be heard as the Fire Suppression System relay kicks in.
Note: Machine will not operate until the Ansul System has been charged and
activated by an Ansul Certified Representative. For a local representative, go
to www.Ansul.com. If connecting to the building alarm system
, this “tie
-
in”
must be made prior to activating the Fire Suppression System.
System Operation and Maintenance
In the event of a fire, the system will automatically activate the Fire Suppression System;
however, if the operator chooses, they can operate the system by pulling the manual pull. The
automatic system utilizes temperature rated fusible links found throughout the Fire Suppression
System. A link (or multiple links) will break in a fire and trigger the automatic Fire Suppression
System to deploy. These links must be inspected and/or serviced by an Ansul Certified
Representative ONLY.
Maintenance must be routinely performed on this system (and in the event of a fire), by an Ansul
Certified Representative; they will advise on the frequency of inspections required. The
representative will thoroughly inspect the entire Fire Suppression System, replace any needed
components, then recharge the system, and ensure it is operational. In the event the system has
been discharged, the Ansul Certified Representative will need to flush the pipes and reactivate
the system.