GL102B Intelligent Temperature Controller 

User’s Guide 

 

 

 

 

1

 

Caution 

Abnormal operating conditions can lead to one or more undesirable events that, in turn, could lead to injury 
to personnel or damage to the equipment or other property. Do not touch the AC terminals while the power 
is supplied to the controller to prevent an electric shock. Make sure power is disconnected while checking 
the unit inside. To minimize the risk of potential safety problems, you should follow all applicable local and 
national codes that regulate the installation and operation of your equipment.  

2

 

Features 

  Compact size, only 48x48x75mm. 

  RTD input (PT100, CU50) or Thermocouple input (T, R, J, B, S, K, E, WRe3-WRe25). 

  Display the temperature in Celsius or Fahrenheit. 

  Universal controller to work with either SSR or mechanical relay. 

  Set control mode to PID or on/off, for either SSR or mechanical relay. 

  When set the main control to SSR output, the internal relay J1, J2 can be set for alarm. When set 

the main control to J2 relay, then J1 relay can be set for alarm. 

3

 

Specifications 

  Power supply: 9-30V DC 

  J1 relay contact capacity: AC250V/3A. 

  Relay contact life: 1x10

5

  SSR control signal: 12V (open-circuit voltage), 30mA (short-circuit current). 

  Temperature accuracy: 0.2%FS. 

  Dimensions: 48x48x75mm. 

  Mounting panel cutout: 45x45mm 

 

Summary of Contents for GL102B

Page 1: ...e the installation and operation of your equipment 2 Features Compact size only 48x48x75mm RTD input PT100 CU50 or Thermocouple input T R J B S K E WRe3 WRe25 Display the temperature in Celsius or Fah...

Page 2: ...respectively and connect the white wire to terminal 8 For two wire PT100 probe connect one wire to terminal 8 and connect the other wire to terminal 9 and short the terminals 9 and 10 The parameter I...

Page 3: ...t next parameter or increase value 3 Down key select previous parameter or decrease value 4 Shift Key Shift the digit when changing the setting or press and hold the key to start auto tune 5 SET key p...

Page 4: ...user can use the key to shift the digit Use the same operation to access the SV and alarm parameters input passcode 0001 after pressing the SET key and PID parameters input passcode 0036 after pressi...

Page 5: ...t SSR as on off control output SV is the control temperature 4 Set J1 relay as alarm output set J2 relay as on off control output SSR output disabled Note 3 Hy Hysteresis Band The parameter Hy is only...

Page 6: ...he accumulated offset that should have been corrected previously The accumulated error is then multiplied by the integral gain and added to the controller output The integral term accelerates the move...

Page 7: ...wer SV value to prevent accident The sensor load heater need to be connected properly otherwise the auto tune will not complete The time for the auto tune depends on the system response time would be...

Page 8: ...output percentage User can use the UP DOWN key to change the percentage manually To switch back to PID mode press and hold the SET key until the AT indicator turns off 11 Examples 11 1 Control a 12V D...

Page 9: ...7 6 11 12 13 14 9 30V DC 24V DC 24V DC Solenoid Valve PT100 R R W Figure 6 Solenoid Valve Wiring 11 3 Control a 110V Heater via SSR 8 9 10 1 2 3 4 5 7 6 SSR 11 12 13 14 110V AC Heating Element N L 3...

Page 10: ...To keep the temperature in a range for example 330 350 F set the output control to on off mode outy 4 keep the cycle time setting ot 2 Set SV 350 Hy 20 The output will be off when temperature goes abo...

Page 11: ...ontrolling a mechanical relay in PID mode change the cycle time ot to 5 60 seconds to save the lifetime of the relay Then you are ready to go For PID mode if the system is not able to hold the tempera...