EN61-DS PS 16 bar
18 / 50
Artikel-Nr. 01 150 50 f
START-UP
After the product has been ASSEMBLED and LEAK TESTING has been carried out
successfully, it is immediately ready for operation.
1.
Start the system by slowly opening the gas feed.
2.
The shut-off fitting of the consumer device must be closed.
3.
Observe the assembly and operating instructions of the consumer device.
4.
Open the shut-off fittings.
Pressure regulator with excess flow valve EFV
1. Close all shut-off fittings on the connected devices.
2. Slowly open the gas vapour or the gas cylinder valve.
If you open the gas vapour or the gas cylinder valve too quickly,
this can result in a short-term pressure increase that triggers the
over-pressure safety device S2SR.
3. Push in the excess flow valve push button, hold this down for
3 seconds until the pressure has equalised.
T he longer the
hose assembly is, the longer you must press the push button.
4. Open all shut-off fittings on the connected devices.
OPERATION
Use this product only when you have carefully read the assembly and operating
manual.
For your own safety, observe all the safety messages in this assembly and
operating manual.
Please also consider the safety of others.
The product can be damaged if the gas cylinder is moved!
Entrained liquid phase can cause the pressure to increase in the LPG system and damage
the product or the LPG system.
Do not move the gas cylinder while the system is in operation.
TROUBLESHOOTING
Fault cause
Action
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the building.
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
Abnormal flame pattern of
non-adjustable pressure
regulator
Compare the nominal outlet pressure of the pressure
regulator with the nominal inlet pressure of the connected
consuming device:
if they do not correspond, replace the pressure regulator
or the gas appliance.
The display unit of the safety
pressure regulator S2SR
(OPC) is set to
RED
Safety pressure regulator S2SR reacted:
switch off gas supply,
allow short bursts of gas to escape from the gas
equipment to achieve pressure equalisation,
if no pressure equalisation is achieved, replace the
pressure regulator.