25
4
English
Programming
2.4 CPS: Curtain Protection System
(only GM-
4
xx-xxxx Series)
CPS is an intelligent declutching mechanism, it allows to manually operate the curtains.
Touch and go: If a stationary hanging curtain is pulled sideways along the system, CPS will
detect movement and the curtain will automatically open or close depending on the pulling
direction.
Touch and Stop: Similarly, if a curtain is already moving, the movement can be stopped by
pulling the curtain in opposite direction from which it is moving.
Manual override: CPS also allows manual operation of the curtains of G-Motion electric
curtain rail systems in case of a power cut. When power returns
and
the curtain has been
moved during the power cut, the system starts recalibrating after the first controlling signal.
Touch and Go or Touch and Stop are set independently in § 2.4.1 and § 2.4.2 below.
Note: CPS response is subject to curtain weight, system layout and chosen treshold values.
CPS is meant as a manual overruling possibility or for occasional use in case the user is unaware
that the system is electrically operated; CPS is not suitable as standard controlling option.
Disclaimer: Though risk of damage is reduced by CPS, CPS cannot entirely prevent curtains or
curtain rail systems from being damaged. CPS is not advised for use in sloped systems.
2.4.1 Touch and Go
motor LED colour orange:
Touch and Go sensitivity is adjustable. For example at higher sensitivity, the motor unit will
pick up de manual operation sooner than at average sensitivity. At lower sensitivity setting,
a larger manual move of the curtain is needed before the motor unit takes over.
This function can also be switched off.
Note: After 15s. without input, the motor unit quits programming mode.
Please read the steps of this feature first before starting.
1. Press and hold the
OPEN
+
CLOSE
buttons until the LED on the motor unit slowly flash-
es white (after ~8s.) (First the LED will turn white continuously, keep the button(s)
pressed)
2. Repeatedly press
OPEN
or
CLOSE
until the LED on the motor unit is orange.
3. Shortly press the
OPEN
+
CLOSE
buttons to enter the feature menu,
4. The LED on the motor unit now flashes orange at the current setting:
5. Cycle through the options below using
OPEN
or
CLOSE:
1x flash
= average sensitivity (Default)
2x flash
= lower sensitivity
3x flash
= higher sensitivity
4x flash
= Off
6. Confirm and store setting by shortly pressing
OPEN
+
CLOSE
buttons.