17
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
For salt water compatible foams, seek advice from the foam agent manufacturers.
FoamLogix
The FoamLogix system consists of three main components:
1) Foam Pump / Motor Assembly.
2) Control Panel (integral with main pump control panel).
3) Flow measurement and injection manifold.
All three elements combine to provide accurate foam proportioning. From the control
panel the operator can initiate the system, adjust the foam ratio, monitor ‘real time’
water flow rate and record total water and foam usage.
The FoamLogix system is powered up when the PTO is engaged. Foam agent is only
injected when the
RED
ON
control button is operated.
The Hale FoamLogix
2.1A
foam proportioning system provides consistent foam
concentrate injection for Class A foam operations and is capable of delivering a ratio
of 0.1% to 1.0% foam concentrate directly into the water discharge stream.
For
3.3
FoamLogix Class A or B foams, the foam concentration will be in the range of
0.1% to 6.0%.
Further information is available in the
FoamLogix Model 3.3 & 5.0
Description,
Installation and Operation manual, part number 029-0020-68-0.
INSTALLATION AND INITIAL SET-UP FOAMLOGIX 2.1A
The following connection points should be considered when installing the WT_C or
WS_C assembly into a vehicle.
Lifting Points
Secure handling of the unit for installation and maintenance is vital. Use only the
lifting points provided on the unit in conjunction with fork Lift Adaptors, part number
60275 / 18
. These items are available from Hale Products Europe.