B l u e B o x
GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0
Fax: -58080-11
Page 20 / 96
www.go-sys.de
3.4 Connecting of the Power Supply
For connecting the power to the BlueBox you need an external 24 VDC power supply.
The power supply is available in two versions:
1. Power supply for the BlueBox (Article-No. 486 K000)
75 W
Input voltage: 88 – 264 VAC
2. Power supply for the BlueBox (Article-No. 486 K001)
150 W
older power supply:
∗
Input voltage: 88 – 132 VAC switchable 176 – 264 VAC
new power supply:
Input voltage: 88 – 264 VAC
Frequency range of all versions: 0 Hz und 47 – 63 Hz
The BlueBox should only be installed by a qualified person using suitable tools. Incorrect instal-
lation can result in serious malfunction and could damage the instrument.
Make sure that your power grid has suitable values.
Please notice that the power supply unit is placed close to the BlueBox because the voltage is declining with
the length of the connecting cable.
Please notice that it is necessary to use the appropriate conductor cable for the environment. In
the outside area it is advisable to use a rubber cable that is approved for the usage site.
Insert the at 24 VDC power supply cable socket into the in the corresponding panel plug of the BlueBox.
∗
siehe
Anhang G – Älteres Netzteil 150 W umschalten 110/230 VAC
24 VDC cablel
230 VAC cable
If the older power supply is
factory set to 88 – 132 VAC,
there is a label here.