GP-PWM-30-SB
12
© 2019 Go Power!
7.2
Setting the Battery Charging Profile
To select the battery charging profile, press and hold the
B Button
. This
will cause the current battery type to flash.
Then, press the
B Button
to toggle through the profile options:
Sealed/Gel, AGM/Lithium (LFP) or Flooded.
To confirm the battery profile, press and hold the
A Button
for 3
seconds.
Non-volatile memory:
Any settings made on the GP-PWM-30-SB will
be saved even when the power has been disconnected from the
controller.
Refer to the Battery Charge Profile Chart below for details on each
profile.
7.3
Battery Charging Profile Chart
Battery Type
SEALED
/GEL
AGM
FLOODED
LFP
Float Charge
@ 25°C:
13.7 VDC (+/- 0.1V)
N/A
Bulk/Absorption Charge
@
25°C:
Set to 30 minutes every
morning.
Applied for 2 hours if
the battery voltage drops
below 12.3 volts.
14.1 VDC
(+/- 0.1V)
14.4 VDC
(+/- 0.1V)
14.4 VDC
(+/- 0.1V)
N/A