Go Power Dura Lite Solar Controller User Manual Download Page 12

SOLAR CONTROLLER 

 

_______________________________________________________________________ 

12 

© 2020 Go Power! 

 

Why does the voltage fluctuate so much when charging with the LITHIUM 

setting? 

Lithium batteries contain smaller battery cells. The voltages of these individual 

cells must be balanced during the charging process by the Battery Management 

System (BMS). Imbalances will cause fluctuations in the battery voltage 

measurement, but this will stabilize as the cells are charged and balanced. 

 

Additionally, lithium batteries have higher resistance than lead acid batteries. 

This affects the charge controller’s battery voltage measurements and its 

compensation for wire resistance. 

 

Reduce wire inductance which may also cause voltage fluctuations. Keep battery 

wires close together, or gently twist positive and negative wires together. 

 

9.0 

Troubleshooting Problems 

How to Read this Section 

Troubleshooting Problems

 is split into three sub-sections, grouped by symptoms 

involving key components. A multimeter or voltmeter may be required for some 

procedures listed.  

 

It is imperative all electrical precautions stated in the Warning Section and 

outlined in the Installation Section are followed. Even if it appears the system is 

not functioning, it should be treated as a fully functioning system generating live 

power. 

 

9.1 

Problems with the Display 

Display Reading:

 Blank   

 

 

Time of Day:

 Daytime/Nighttime   

 

Possible Causes:  

Battery or fuse connection and/or solar array connection  

(Daytime only) or battery or fuse connection (Nighttime only). 

 

How to tell:  

Check the voltage at the controller battery terminals with a voltmeter and 

compare with a voltage reading at the battery terminals. 

 

If there is no voltage reading at the controller battery terminals, the problem could 

be a fuse, or the wiring between the battery and the controller. If the battery 

voltage is lower than 6 volts the controller will not function.  

 

For the solar array, repeat steps 1 and 2 substituting all battery terminals with 

solar array terminals. 

 

 

Remedy:   

Summary of Contents for Dura Lite Solar Controller

Page 1: ...Solar Controller User Manual ________________________________________________________________________ 2020 Go Power User Manual 30 amp Single Bank Solar Controller...

Page 2: ...T SAFETY INSTRUCTIONS 4 3 0 Choosing a Battery 6 4 0 DuraLite Kit Wiring Diagram 6 5 0 Operating Instructions 6 5 1 Battery Charging Profile Chart 8 6 0 Errors Troubleshooting 9 7 0 Display Symbols 10...

Page 3: ...ystem voltage and is rated for a maximum continuous DC input current of 37 5A and input voltage of 35VDC Per National Electrical Code NEC article 690 7 and 690 8 PV module nameplate ratings must be mu...

Page 4: ...Current 30A Max PV Open Circuit Voltage 50V Battery Type Sealed AGM Gel Flooded Lithium 1 12V and Lithium 2 24V Self consumption 4 2mA 12V 2 6mA 24V Temperature Compensate Coefficient 3mV 2V Default C...

Page 5: ...ion Use extreme caution when working with electricity and when handling and working around batteries Observe correct polarity Reverse polarity of the Battery 1 terminals will cause the controller to g...

Page 6: ...fety instructions 4 0 DuraLite Kit Wiring Diagram The SOLAR CONTROLLER Maximum 37 5A rating is based on a 30 amp total maximum short circuit current rating Isc from the solar modules nameplate ratings...

Page 7: ...ess the SET button to clear the generated energy 3 Switch the battery temperature unit Press the SET button and hold 5s under the battery temperature interface 4 Battery type Battery type Sealed Gel F...

Page 8: ...m Sealed Gel Flooded Lithium Over Voltage Disconnect Voltage 16 0V 16 0V 16 0V 14 6 29 2V Charging Limit Voltage 15 0V 15 0V 15 0V 14 4 28 8V Over Voltage Reconnect Voltage 15 0V 15 0V 15 0V 14 4 28 8...

Page 9: ...min and boost duration is 10 to180min 2 When setting a lithium battery type for example a LiFePO4 use these rules when setting voltage parameters Over Voltage Disconnect Voltage Charging Limit Voltage...

Page 10: ...ing Solution This is an Over Discharge Error The battery voltage is too low Connect the DuraLite kit to charge the battery 7 0 Display Symbols Icon Motion Issue Solid The system is normal but not char...

Page 11: ...ed when compared with readings from another voltmeter There may be a slight difference between the battery voltage displayed on the SOLAR CONTROLLER display and the battery voltage measured at the bat...

Page 12: ...oblems is split into three sub sections grouped by symptoms involving key components A multimeter or voltmeter may be required for some procedures listed It is imperative all electrical precautions st...

Page 13: ...ssible Cause Excessive voltage drop from batteries to controller due to loose connections small wire gauge or both How to tell Check the voltage at the controller battery terminals with a voltmeter an...

Page 14: ...clean tight and secure Continue with the solutions below for additional help on low current readings Current Reading Less than expected Time of Day Daytime clear sunny skies Possible Causes 1 Current...

Page 15: ...itive and negative terminals of each module junction box with either the positive or the negative wires disconnected from the terminal Remedy 2 Reconnect in correct configuration Tighten all connectio...

Page 16: ...oper hook up Acts of God including lightning floods earthquakes fire and high winds Damage in handling including damage encountered during shipment This warranty shall be considered void if the warran...

Page 17: ...ER _______________________________________________________________________ 17 2020 Go Power 2019 GO POWER 201 710 Redbrick St Victoria British Columbia Canada V8T 5J3 MOBI_MAN_SOLAR CONTROLLER _RevF g...

Reviews: