Go Power Dura Lite Solar Controller User Manual Download Page 10

SOLAR CONTROLLER 

 

_______________________________________________________________________ 

10 

© 2020 Go Power! 

 

Solution 2 

Your battery may be

 

too

 

far discharged to accommodate the controller. Keep the 

solar kit plugged in and placed in full sun for a few hours and try the controller 

again.  

 

 Flashing 

Solution  

This is an Overvoltage Error. The battery voltage is too high. Disconnect the 

DuraLite kit and plug in a power draw to lessen the voltage in the battery.  

 

 Flashing 

Solution  

This is an Over Discharge Error. The battery voltage is too low. Connect the 

DuraLite kit to charge the battery.  

 

 

7.0 

Display Symbols 

Icon 

Motion 

Issue 

 

Solid 

The system is normal but not 

charging 

Energy bars are 

Flashing 

Charging 

 

Solid 

Full 

Flashing 

Battery Overvoltage 

 

Flashing 

Battery Over Discharge 

 

 

 

8.0 

Frequently Asked Questions 

(FAQs) 

Before a problem is suspected with the system, read this section. There are 

numerous events that may appear as problems but are in fact perfectly normal. 

Please visit 

https://gpelectric.com/support/

 for the most up-to-date FAQs and 

troubleshooting videos. 

 

It seems like my flooded batteries are losing water over time. 

Summary of Contents for Dura Lite Solar Controller

Page 1: ...Solar Controller User Manual ________________________________________________________________________ 2020 Go Power User Manual 30 amp Single Bank Solar Controller...

Page 2: ...T SAFETY INSTRUCTIONS 4 3 0 Choosing a Battery 6 4 0 DuraLite Kit Wiring Diagram 6 5 0 Operating Instructions 6 5 1 Battery Charging Profile Chart 8 6 0 Errors Troubleshooting 9 7 0 Display Symbols 10...

Page 3: ...ystem voltage and is rated for a maximum continuous DC input current of 37 5A and input voltage of 35VDC Per National Electrical Code NEC article 690 7 and 690 8 PV module nameplate ratings must be mu...

Page 4: ...Current 30A Max PV Open Circuit Voltage 50V Battery Type Sealed AGM Gel Flooded Lithium 1 12V and Lithium 2 24V Self consumption 4 2mA 12V 2 6mA 24V Temperature Compensate Coefficient 3mV 2V Default C...

Page 5: ...ion Use extreme caution when working with electricity and when handling and working around batteries Observe correct polarity Reverse polarity of the Battery 1 terminals will cause the controller to g...

Page 6: ...fety instructions 4 0 DuraLite Kit Wiring Diagram The SOLAR CONTROLLER Maximum 37 5A rating is based on a 30 amp total maximum short circuit current rating Isc from the solar modules nameplate ratings...

Page 7: ...ess the SET button to clear the generated energy 3 Switch the battery temperature unit Press the SET button and hold 5s under the battery temperature interface 4 Battery type Battery type Sealed Gel F...

Page 8: ...m Sealed Gel Flooded Lithium Over Voltage Disconnect Voltage 16 0V 16 0V 16 0V 14 6 29 2V Charging Limit Voltage 15 0V 15 0V 15 0V 14 4 28 8V Over Voltage Reconnect Voltage 15 0V 15 0V 15 0V 14 4 28 8...

Page 9: ...min and boost duration is 10 to180min 2 When setting a lithium battery type for example a LiFePO4 use these rules when setting voltage parameters Over Voltage Disconnect Voltage Charging Limit Voltage...

Page 10: ...ing Solution This is an Over Discharge Error The battery voltage is too low Connect the DuraLite kit to charge the battery 7 0 Display Symbols Icon Motion Issue Solid The system is normal but not char...

Page 11: ...ed when compared with readings from another voltmeter There may be a slight difference between the battery voltage displayed on the SOLAR CONTROLLER display and the battery voltage measured at the bat...

Page 12: ...oblems is split into three sub sections grouped by symptoms involving key components A multimeter or voltmeter may be required for some procedures listed It is imperative all electrical precautions st...

Page 13: ...ssible Cause Excessive voltage drop from batteries to controller due to loose connections small wire gauge or both How to tell Check the voltage at the controller battery terminals with a voltmeter an...

Page 14: ...clean tight and secure Continue with the solutions below for additional help on low current readings Current Reading Less than expected Time of Day Daytime clear sunny skies Possible Causes 1 Current...

Page 15: ...itive and negative terminals of each module junction box with either the positive or the negative wires disconnected from the terminal Remedy 2 Reconnect in correct configuration Tighten all connectio...

Page 16: ...oper hook up Acts of God including lightning floods earthquakes fire and high winds Damage in handling including damage encountered during shipment This warranty shall be considered void if the warran...

Page 17: ...ER _______________________________________________________________________ 17 2020 Go Power 2019 GO POWER 201 710 Redbrick St Victoria British Columbia Canada V8T 5J3 MOBI_MAN_SOLAR CONTROLLER _RevF g...

Reviews: