background image

D6072-096 

- SIL 2 Thermocouple/mV Repeater

 

G.M. International ISM0437-6 

SIL 2 Thermocouple/mV Repeater, DIN-Rail 

Models D6072S-096, D6072D-096 

 

D6072S-096 - D6072D-096 

INSTRUCTION MANUAL 

Summary of Contents for D6072S-096

Page 1: ...D6072 096 SIL 2 Thermocouple mV Repeater G M International ISM0437 6 SIL 2 Thermocouple mV Repeater DIN Rail Models D6072S 096 D6072D 096 D6072S 096 D6072D 096 INSTRUCTION MANUAL ...

Page 2: ...to 90 step Output range 10 to 100 mV Performance Ref Conditions 24 V supply 23 1 C ambient temperature slow integration mode Input Calibration and linearity accuracy 10 µV Temperature influence 3 µV C typical Output Calibration and linearity accuracy 10 µV Temperature influence 3 µV C typical Compatibility CE mark compliant conforms to Directive 2014 34 EU ATEX 2014 30 EU EMC 2014 35 EU LVD 2011 6...

Page 3: ... Functional Safety Certification High Density two channels per unit Simplified installation using standard DIN Rail and plug in terminal blocks with or without Power Bus Data logging and monitoring via software Input Ch1 for thermocouple TC or for millivolt source Terminal block connections Input Ch1 for thermocouple TC or for millivolt source Input Ch2 for thermocouple TC or for millivolt source ...

Page 4: ... 24 Vdc mV Out 1 B SIL 2 In 1 TC mV MODEL D6072D 096 Duplicator SAFE AREA ZONE 2 GROUP IIC T4 NON HAZARDOUS LOCATIONS CLASS I DIVISION 2 GROUPS A B C D T Code T4 5 6 1 2 3 4 7 12 MODEL D6072D 096 mV Out 1 SIL 2 11 8 F Power and Fault Bus Supply 24 Vdc mV Out 2 SIL 2 In 1 In 2 TC mV TC mV MODEL D6072S 096 F Power and Fault Bus 5 6 1 2 7 mV Out 1 SIL 2 8 Supply 24 Vdc In 1 TC mV ...

Page 5: ...allations check the area to be nonhazardous before servicing Connect only one individual conductor per each clamping point use conductors up to 2 5 mm2 13 AWG and a torque value of 0 5 0 6 Nm Use only cables that are suitable for a temperature of at least 85 C The wiring cables have to be proportionate in base to the current and the length of the cable In case of installation in zone 2 the connect...

Page 6: ...38 to 1832 270 to 1000 454 to 1832 0 050 0 090 J IEC 60584 GOST 8 585 ASTM E230 50 90 0 2 0 4 150 to 1200 238 to 2192 210 to 1200 346 to 2192 0 050 0 090 K IEC 60584 GOST 8 585 ASTM E230 50 90 0 3 0 5 150 to 1372 238 to 2502 270 to 1372 454 to 2502 0 050 0 090 L type L DIN DIN 43710 50 90 0 2 0 4 200 to 900 328 to 1652 200 to 900 328 to 1652 0 050 0 090 LR type L GOST GOST 8 585 50 90 0 3 0 5 200 ...