- SIL 2 Repeater Power Supply
G.M. International ISM0397-3
SIL 2 Repeater Power Supply Hart,
DIN-Rail and Termination Board
Models D5015SS, D5015SK
D5015SS - D5015SK
INSTRUCTION MANUAL
Page 1: ...D5015 SIL 2 Repeater Power Supply G M International ISM0397 3 SIL 2 Repeater Power Supply Hart DIN Rail and Termination Board Models D5015SS D5015SK D5015SS D5015SK INSTRUCTION MANUAL...
Page 2: ...of full scale Linearity error 0 05 of full scale Supply voltage influence 0 02 of full scale for a min to max supply change Load influence 0 02 of full scale for a 0 to 100 load resistance change Temp...
Page 3: ...ion T V Functional Safety Certification Simplified installation using standard DIN Rail and plug in terminal blocks with or without Power Bus or customized Termination Boards 250 Vrms Um max voltage a...
Page 4: ...d the limits Co Ca Lo La Lo Ro given in the Associated Apparatus parameters for the effective group See parameters indicated in the table below D5015 Terminals Ch1 7 8 Uo Voc 1 1 V Ch1 8 11 Io Isc 92...
Page 5: ...Groups I IIA IIB and 600 nF for Group IIC If the cable parameters are unknown the following value may be used Capacitance 200 pF per meter 60 pF per foot Inductance 1 H per meter 0 20 H per foot Must...
Page 6: ...he connecting cables of non intrinsically safe circuits must be safely routed in a cable duct or similar The distance between the pluggable connection terminal and the cable duct should not exceed 500...