Chapter1. Brief Introduction

SDV08 signal divider is used with VSD-F2L4 controller or VSP-F2L4 controller. SDV08 signal divider is 

mainly used to convert, distribute, relay and copy the signal of the controller's inputs, so as to achieve signal 

hot backup and signal long distance transmission.

Parameter List

1

Power Input

Input/output Interface

Controllable Pixel

Controllable Pixel for One Port

110V

~

220V

AC

50

/

60Hz

3A

Neutrik connector

RJ45

),

ST optical connector

2048*600pixel
2048*300pixel
CCC/CE/ROHS/TUV
Network cable≤120m, Single Mode Fiber ≤10km, Signal can be cascaded

Certificate

Transmission Distance

Power input/output port: 

Input Single-phase AC 110V~240V and can be transmitted to next SDV08 

by output port. 

Standby Electrical outlet: 

Provide Single-phase AC110V~240V.

Group A signal input/output port: 

SIG IN represents group A signal input port.SIG OUT represents 

group A signal cascade output port.

Group B signal input/output port:

 SIG IN represents group B signal input port.SIG OUT represents 

group B signal cascade output port.

Optical fiber signal input/output port:

 IN /OUT stand for optical fiber signal input/output port.

Signal  light  indicator: 

There  are  two  light  indicators  which  show  the  working  state  of  group A  and 

group B, the relevant indicator will twinkle when there is signal input. 

Power

Switch

Group A signal

output ports

SIG

A1

SIG

A2

SIG

A3

SIG

A4

SIG

B1

SIG

B2

SIG

B3

SIG

B4

Power switch:

 The power switch of signal divider.

Signal output ports Group A:

 SIG A1~SIG A4 are the output signal interfaces of group A and can be 

connected to the LED screen directly.

Signal output ports Group B: 

SIG B1~SIG B4 are the output signal interfaces of group B and can be 

connected to the LED screen directly.

Introduction

Power

input

/

output

port

Group B signal

input/output port

Signal

light

indicator

Standby

electrical

Outlet

Optical

fiber

signal

input

/

output

port

Handing parts

Group A signal

input/output port

1.1

 

The Front Side of SDV Signal Divider:

1.2

 

The Back Side of SDV Signal Divider:

Group B signal

output ports

Summary of Contents for SDV08

Page 1: ...Glux SDV divider manual GLUX Visual Effects Tech Shenzhen Co Ltd...

Page 2: ...l Cascade of Signal Divider 2 1 Interface De nition of Signal Divider 2 2 Common Methods for Signal Cascade Chapter3 Function Introduction of Signal Divider 3 1 Signal Transformation 3 2 Signal Distri...

Page 3: ...B signal input output port SIG IN represents group B signal input port SIG OUT represents group B signal cascade output port Optical ber signal input output port IN OUT stand for optical ber signal i...

Page 4: ...A4 SIG A3 SIG A2 SIG A1 Equal 1 3 Outline Size and Installation Diagram Hanging Handing parts 1 4 Structural Diagram Hanger Screw BM4 50 SDV Top box Hanger inner mat Screw PA2 8 Optical ber block Scre...

Page 5: ...ade way SIG B4 SIG B3 SIG B2 SIG B1 SIG A4 SIG A3 SIG A2 SIG A1 SIG B8 SIG B7 SIG B6 SIG B5 SIG A8 SIG A7 SIG A6 SIG A5 Optical fiber signal cascade output Signal Divider 1 SDV 1 1 Optical ber signal...

Page 6: ...only use the intelligent setting method to set the display address of the LED screen if there is one or more signal divider connected with VSP F2L4 controller Please select correct controller port and...

Page 7: ...he backup signal input port and connect to the last LED panel s output Thereby ensuring there are main signal and backup signal on the screen at the same time 4 Application Example Application Example...

Page 8: ...1024 384 we can calculate W 1024 H 384 according to the signal horizontal segmentation of the VSP F2L4 controller The parameter interface showed as below Step3 Addresses Setting of Signal Divider We c...

Page 9: ...way of port OUT2 The address distribution of B1 is as the red arrow shown below Addresses Setting steps for Main Signal Main Signal A1 Port setting Controller port A Signal divider port 1 1 represents...

Page 10: ...on way of port OUT1 The address distribution of A2 is reverse to the A1 as the red arrow shown below Backup signal B2 Port setting Controller port B Signal divider port 2 2 represents B2 Fill in the c...

Page 11: ...parameter interface and click Save button when you have completed all of the address settings Otherwise once you reboot the controller the data for addresses setting will be lost and the image of the...

Page 12: ...The way to set the address of Port A2 Select Controller port A Divider port 2 Rows 6 Columns 4 rebuild a simulator diagram Number the addresses blocks of the second column to set the addresses of por...

Page 13: ...f the fourth column to set the addresses of port A4 as shown below Please return to the parameters interface and click Save button to save the addresses setting data when you complete all addresses se...

Page 14: ...onal injury use the appropriate power line Please only use the dedicated power cord for this product which acquire the international regional certi cation Connect and Disconnect Properly When add Conn...

Page 15: ...alZone NanshanDistrict Shenzhen China tel 86 755 88866999 fax 86 755 86241789 Factory GluxIndustrialZone Donghuan2ndRoad LonghuaNewDistrict Shenzhen GuangdongChina tel 86 755 29174931 fax 86 755 86232...

Reviews: