background image

In

s

tr

u

c

ti

o

n

 M

a

n

u

a

l        

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

W

W

W

W

W

C

C

C

 

 

 

&

&

&

 

 

 

C

C

C

C

C

C

W

W

W

 

 

from software version 1.00/03  
(Instruction version 1.14)

 

 

e-mail: [email protected] 

Internet: http://www.glp.de 

Summary of Contents for IMPRESSION 120 RZ WWC

Page 1: ...Instruction Manual W W WW W WC C C C C CC C CW W W from software version 1 00 03 Instruction version 1 14 e mail service glp de Internet http www glp de...

Page 2: ...systems the I IM MP PR RE ES SS SI IO ON N 1 12 20 0 R RZ Z W WW WC C as well as the I IM MP PR RE ES SS SI IO ON N 1 12 20 0 R RZ Z C CC CW W The two systems differ from each other only by the number...

Page 3: ...2 1 1 Mounting on the floor upright 7 2 1 2 Mounting in hanging position head down 8 2 1 3 Mounting in a sideway position 8 2 2 Securing the Device 9 2 3 Connections 9 2 3 1 Power Supply 9 2 3 2 DMX 1...

Page 4: ...1 Moving head actively and passively cooled 2 Arm with various cooling vents 3 LCD Display Menu data entry 4 Base with various connectors and Camlock mounting system 1 2 3 4 5 base side 1 6 base side...

Page 5: ...able parts Opening the fixture will void the manufacturers warranty 6 Danger of burning Wait at least 15 minutes after disconnecting the AC power before changing the optical carrier on the fixture Pay...

Page 6: ...entioned in this manual 11 Use only original spare parts Any structural modification on the system will terminate all warranty claims 12 Please keep this instruction manual for future reference 2 Prep...

Page 7: ...quick release fasteners front side of the fixture 2 1 1 Mounting on the floor upright To operate the I IM MP PR RE ES SS SI IO ON N in an upright position please use the dedicated floor stand which sh...

Page 8: ...To operate the I IM MP PR RE ES SS SI IO ON N in a sideways position please use an additional mounting bar available from GLP or one of their agents This mounting bar is fixed via the two camlock quic...

Page 9: ...can be attached to the fixture by threading it through one of the two holes provided on the base of the fixture Ensure that the safety wire is securely fastened through the fixture and the fixtures mo...

Page 10: ...Manual DMX Manual control of all system functions Pan Manual control for Pan X movement Speed Movements Speed adjustment for Pan Tilt movements see also item below Pan Tilt Movements Manual control fo...

Page 11: ...MX Image Stores the Scene currently sent to the unit DOWN UP DMX input Monitor Indicates the presently received DMX signal per DMX channel Pan Instantaneous value for Pan Speed Movements Speed adjustm...

Page 12: ...the system 0 100 0 255 00 FF 0 100 7 Shutter Shutter closed 0 15 00 0F 0 5 5 Random Pulse effect slow fast 16 47 10 2F 6 18 5 Up dimming then Shutter closing random patterns slow fast 48 79 30 4F 19...

Page 13: ...de 9 DMX channels Channel Function Time and Value DMX HEX 1 PAN coarse 0 660 3 2 s 0 255 00 FF 0 100 2 PAN fine High Pos High Pos 2 6 16 Bit 0 255 00 FF 0 100 3 Tilt coarse 0 300 1 5 s 0 255 00 FF 0 1...

Page 14: ...79 30 4F 19 31 5 Shutter open then down dimming random patterns slow fast 80 111 50 6F 32 43 Up dimming then down dimming random patterns slow fast 112 143 70 8F 44 56 Strobe effect pause 5s to 1s 14...

Page 15: ...hat the fixture is kept clean and that dust dirt and smoke fluid residues must not build up on or within the fixture If they do the fixture s light output will be significantly reduced and damages to...

Page 16: ...ted overheating switch Mounting Position Any see chapter mounting Lighting System Additive Color mixing LED Type 120x Rebel High power LEDs Lifetime 50 000 h CCW version 78x LEDs cold white 42x LEDs w...

Page 17: ...lamps 8 I Instruction Version 1 Internet 1 L LED Class 2M 5 M Maintenance 15 Menu Field 10 Micro fuse 9 Mode key 10 Mounting 6 Mounting in hanging Position 8 Mounting in sidewise Position 8 Mounting o...

Page 18: ...W W WW W WC C C C C CC C CW W W GLP German Light Products GmbH Instruction version 1 14 from software version 1 00 03 18...

Reviews: