GLP Fusion XPAR 12Z Quick Start And Safety Manual Download Page 10

www.glp.de

 

Avoiding damage to the fixture

 

 

 

10 

 

Fusion XPAR 12Z Quick Start and Safety Manual Rev. A

 

 

2.

 

Avoiding damage to the fixture 

Important! Follow the directions in this section carefully, or the fixture may suffer damage 
that is not covered by the product warranty. 

General precautions 

Do not drop the fixture or expose it to mechanical stress. 
Protect the onboard OLED display and control panel from shocks, or they may suffer 
damage that is not covered by the product warranty. 
Do not expose the fixture to heat (from other lighting fixtures for example). 
Clean optical components only as directed. Oils, solvents, and other chemicals commonly 
used for cleaning can damage the lens coatings and surfaces. 
Use only original spare parts. Do not make any structural modifications to the fixture or you 

will void the product warranty. 

Avoiding damage from light sources and heat 

To avoid problems from strong light sources:  

● 

Do not expose the front of the fixture to sunlight or any other strong light source. 

● 

In outdoor applications during daylight, make sure that the front face of the fixture is 
shielded or points away from the sun, even when not in use. 

● 

Do not aim other high-powered beam lights directly at the fixture. 

Do not operate the fixture in ambient temperatures above 40° C / 104° F. Allow free airflow 
around the fixture. 

IP rating 

XPAR 12Z fixtures are IP65-rated: 

● 

IP

 stands for Ingress (entry into the fixture) Protection. 

● 

The first figure 

6

 in the rating means that fixtures are protected against the entry of dust 

and airborne particles. 

● 

The second figure 

in the rating means that fixtures are protected against the entry of 

rain and water projections from all angles. Fixtures are not protected against immersion 
in water and they are not protected against high-pressure water jets. 

Avoiding damage from water and humidity 

● 

Do not install XPAR 12Z fixtures in a location where water can pool around the fixture or 
allow XPAR 12Z fixtures to become submerged in any other way. Do not aim low- or high-
pressure water jets at fixtures. 

● 

Keep all unused connectors on the fixture sealed with their protective caps, both when 
the fixture is being used and when it is not in use. 

● 

In outdoor and high-humidity environments, use IP65-rated power and data connectors 
and cable (an IP65 rating means that the item is protected against the entry of water 
from rain, projections and low-pressure jets as well as the entry of dust). When assembling 

connectors and installing them on cable, follow the manufacturer’s and ensure that an 

Summary of Contents for Fusion XPAR 12Z

Page 1: ...Fusion XPAR 12Z Quick Start and Safety Manual Software version 1 0 0 0...

Page 2: ...ted companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information...

Page 3: ...overview 12 4 Installation 14 Permitted mounting options 14 Securing fixtures with a safety cable 14 Installing on a surface at any angle 15 Installing on a rigging truss or similar structure 16 Free...

Page 4: ...Thermal 26 Included items 27 Accessories optional 27 Dimensions and weight 27 10 Dimensions 28...

Page 5: ...Fusion XPAR 12Z lighting fixtures consists of This document the XPAR 12Z User Manual available for download from www glp de The User Manual contains important safety information and installation instr...

Page 6: ...sult software release notes and download the correct version of this manual on the GLP website if necessary Make all user documentation available to all installers and operators Save this document for...

Page 7: ...er input cable is rated as follows US power cable 16 A 14 AWG UL listed E304117 SJT 4 9 ft EU power cable 16 A 1 5 mm H07RN F 1 5 m Do not connect more than twelve 12 Fusion XPAR 12Z fixtures to power...

Page 8: ...tical radiation emitted Do not stare into the light output from the fixture May be harmful to the eyes Do not look at the fixture s light output with optical instruments or any device that may concent...

Page 9: ...urpose Do not use a safety cable as the primary means of support Check that installation hardware is in perfect condition Fasteners must be steel grade 8 8 strength or better Rigging clamps must be ha...

Page 10: ...other high powered beam lights directly at the fixture Do not operate the fixture in ambient temperatures above 40 C 104 F Allow free airflow around the fixture IP rating XPAR 12Z fixtures are IP65 r...

Page 11: ...ry provide extra cable slack and create drip loops before connectors Create loose cable bends only Do not subject connections to bending forces or allow connections to bear the weight of long lengths...

Page 12: ...IP65 rating mean that it can also be used outdoors in temporary installations if precautions are taken to prevent immersion in water and damage from direct sunlight It can be fixed to any surface or...

Page 13: ...t 5 pin XLR 9 DMX in 5 pin XLR 10 Power in TRUE1 compatible 11 Power loop through TRUE1 compatible Fixture control This Quick Start and Installation Manual gives a very basic overview of installation...

Page 14: ...odes and legal requirements Note the requirement to secure lighting fixtures with safety cables in temporary installations Permitted mounting options An XPAR 12Z fixture may be installed in one of the...

Page 15: ...le 1 Check that the surface is secure and can safely hold the weight of the fixture plus all hardware and cables 2 Loosen the handwheels on the mounting bracket adjust the bracket to a suitable angle...

Page 16: ...ng vertically downwards from a horizontal rigging truss or pipe you can fasten it to the truss using a G clamp If you are going to install the fixture in any other orientation you must use a half coup...

Page 17: ...fixture can be adjusted by varying the mounting bracket position Figure 5 Free standing on a surface 1 Loosen the handwheel bolts either side of the mounting bracket 2 Split the bracket into its two...

Page 18: ...leaner appearance by removing the handwheel bolts on either side Figure 6 Free standing as uplighter 1 Unscrew the handwheel bolts either side of the mounting bracket and remove the mounting bracket i...

Page 19: ...to an external dimmer The XPAR 12Z does not have a power ON OFF switch Power is applied to the fixture as soon as the power cable becomes live The XPAR 12Z has a 3 conductor TRUE1 compatible Mains IN...

Page 20: ...ower in one chain at 200 240 V 50 Hz The power input cable supplied with the fixture is rated 16 A maximum Add together the maximum current draw ratings of all the devices that you intend to connect t...

Page 21: ...in use The XPAR 12Z has two 5 pin XLR connectors for IN and THRU connections to a DMX data link XPAR 12Z fixtures support the USITT DMX 512A signal protocol They also support RDM Remote Device Managem...

Page 22: ...s of the barndoors are correctly held in place 2 Install a safety bond between one of top corners of the barndoors assembly and the main fixture to prevent the barndoors falling if they become detache...

Page 23: ...Z s TRUE1 compatible mains power input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is sti...

Page 24: ...is DMX 10 or above Channels 5 8 have no effect The CTC and M G shift channels modify the color selected by the other channels A Control Settings channel lets you configure the fixture remotely via DMX...

Page 25: ...DMX Mode 4 RGB L 1 Zoom 2 Control 3 Red 4 Green 5 Blue 6 Lime DMX Mode 5 White operates the fixture as a white light with controllable Color Temperature and Green magenta shift A Control Settings cha...

Page 26: ...Operating position Any Minimum distance to combustible materials 0 2 m 8 in Minimum distance to illuminated surfaces 0 2 m 8 in Installation environment Temporary or permanent indoor installation temp...

Page 27: ...and Safety Manual Rev A 27 Included items Power cable with TRUE1 compatible mains input plug Accessories optional Filter frame Barn Door attachment Dimensions and weight Length 245mm 9 6 ins Width 24...

Page 28: ...www glp de Dimensions 28 Fusion XPAR 12Z Quick Start and Safety Manual Rev A 10 Dimensions All dimensions are in millimeters...

Page 29: ...Fusion XPAR 12Z Quick Start and Safety Manual Rev A 29...

Reviews: