background image

www.glp.de

 

DMX MODE 1

 

 

34 

 

 

EXO Wash User Manual Rev. B

 

 

13  Control / 

Settings 

No function 

0.0 

3.5 

Snap 

Dimmer curve: Extra-soft (3s hold) 

10 

15 

3.9 

5.9 

Dimmer curve: Linear (3s hold) 

16 

21 

6.3 

8.2 

Display mode: Auto (3s hold)

 

22 

27 

8.6 

10.6 

Display mode: On (3s hold) 

28 

33 

11.0 

12.9 

Display mode: Off (3s hold)

 

34 

39 

13.3 

15.3 

Display orientation: Normal (3s hold)  

40 

45 

15.7 

17.6 

Display orientation: Inverted (3s hold) 

46 

51 

18.0 

20.0 

No DMX: Blackout (3s hold) 

52 

57 

20.4 

22.4 

No DMX: Hold (3s hold) 

58 

63 

22.7 

24.7 

No DMX: Stand-alone (3s hold) 

64 

69 

25.1 

27.1 

Fan mode: Regulated (3s hold)

 

70 

75 

27.5 

29.4 

Fan mode: High (3s hold) 

76 

81 

29.8 

31.8 

Fan mode: Medium (3s hold)

 

82 

87 

32.2 

34.1 

Fan mode: Low (3s hold) 

88 

93 

34.5 

36.5 

Position feedback: Off (3s hold) 

94 

99 

36.9 

38.8 

Position feedback: On (3s hold)

 

100 

105 

39.2 

41.2 

No function 

106 

117 

41.6 

45.9 

Tilt inversion: Off (3s hold)

 

118 

123 

46.3 

48.2 

Tilt inversion: On (3s hold)

 

124 

129 

48.6 

50.6 

Pan inversion: Off (3s hold) 

130 

135 

51.0 

52.9 

Pan inversion: On (3s hold) 

136 

141 

53.3 

55.3 

Zoom inversion: Off (3s hold)

 

142 

147 

55.7 

57.6 

Zoom inversion: On (3s hold)

 

148 

153 

58.0 

60.0 

Defog: Off

 

154 

159 

60.4 

62.4 

Defog: On 

160 

165 

62.7 

64.7 

Defog: Quick

 

166 

171 

65.1 

67.1 

Load Settings Preset1 

172 

177 

67.5 

69.4 

Load Settings Preset2 

178 

183 

69.8 

71.8 

Load Settings Preset3

 

184 

189 

72.2 

74.1 

PWM 600 Hz (5s hold) 

190 

195 

74.5 

76.5 

PWM: 2200 Hz (5s hold) 

196 

201 

76.9 

78.8 

PWM: 3000 Hz (5s hold)

 

202 

207 

79.2 

81.2 

PWM: 4800 Hz (5s hold)

 

208 

213 

81.6 

83.5 

PWM: 9600 Hz (5s hold) 

214 

219 

83.9 

85.9 

PWM: 25 kHz (5s hold) 

220 

225 

86.3 

88.2 

No function 

226 

231 

88.6 

90.6 

Return to default settings 

232 

237 

91.0 

92.9 

Reset Pan/Tilt (3s hold)

 

238 

243 

93.3 

95.3 

Reset Head (3s hold) 

244 

249 

95.7 

97.6 

Reset All (3s hold) 

250 

255 

98.0 

100 

Summary of Contents for Fusion EXO Wash 30

Page 1: ...Fusion EXO Wash 30 User Manual Software version V1 0 00...

Page 2: ...d companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information c...

Page 3: ...and Support 12 3 EXO Wash 30 overview 13 4 Installation 15 Permitted mounting options 15 Securing fixtures with a safety cable 15 Installing on a rigging truss or similar structure 16 Standing on a ho...

Page 4: ...trol modes overview 30 12 DMX control channel layout tables 33 DMX Mode 1 Compact 33 DMX Mode 2 Standard 35 DMX Mode 3 Extended 39 13 Service 48 Cleaning 48 GLP Service and Support 48 14 Technical spe...

Page 5: ...0 DMX Channel Index available for download from www glp de The Channel Index is a separate guide to the DMX control channel layout and DMX commands available All documents are available for download f...

Page 6: ...d on the fixture Refer all repairs and any service operation not described in this manual to a technician authorized by GLP The light source in this fixture must not be changed by the end user Read an...

Page 7: ...requency at the Mains OUT socket are the same as the voltage and frequency applied to the Mains IN socket Only connect devices to the Mains Out socket that accept this voltage and frequency Fusion EXO...

Page 8: ...ersons near to or working on the fixture are not looking directly into the light output when the fixture lights up suddenly This can happen when power is applied when the fixture receives a DMX signal...

Page 9: ...r Rigging clamps must be half coupler type that completely encircle the rigging truss chord If the fixture is installed in a location where it may cause injury or damage if it falls install as directe...

Page 10: ...duct warranty Avoiding damage from light sources and heat Do not point the front of the fixture towards the sun or other strong light sources Strong light can cause internal damage to the fixture melt...

Page 11: ...65 rating means that the item is protected against the entry of water from rain projections and low pressure jets as well as the entry of dust When assembling connectors and installing them on cable f...

Page 12: ...r a suitably designed flight case to protect it from damage caused by shocks during transportation Release the tilt lock and support the fixture s head with the original packaging inserts or flight ca...

Page 13: ...he fixture has a built in battery to allow the display to be operated for setup before mains power is connected The EXO Wash 30 can be used indoors in permanent and temporary installations Its rugged...

Page 14: ...2 Head 3 Tilt lock 4 Yoke 5 Base 6 Control panel 7 Rubber feet 8 Wireless indicator 9 Battery button 10 PowerCON TRUE1 input 11 Mode Esc button 12 Up button 13 Down button 14 Enter button 15 Optional...

Page 15: ...tion and that meets all applicable codes and legal requirements Note the requirement to secure lighting fixtures with safety cables in temporary installations Permitted mounting options An EXO Wash 30...

Page 16: ...re 4 Fasten the safety cable through the slot B on the underside of the fixture base Check that the fixture is now secured Installing on a rigging truss or similar structure You can suspend an EXO Was...

Page 17: ...nd yoke of the fixture will not collide with any fixed objects as the fixture moves Ensure that the fixture has sufficient clearance to any adjacent surfaces or objects 5 Secure the fixture with a saf...

Page 18: ...nal auto sensing power supply accepts AC power at 100 240 V 50 60 Hz Do not connect the fixture to power at any other voltage or to an external dimmer The EXO Wash 30 does not have a power ON OFF swit...

Page 19: ...ore than four 4 EXO Wash 30 fixtures in total to power in one chain at 100 120 V 60 Hz Do not connect more than eight 8 EXO Wash 30 fixtures in total to power in one chain at 200 240 V 50 Hz The power...

Page 20: ...Wash 30 has two 5 pin XLR sockets for IN and THRU connections to a DMX data link EXO Wash 30 fixtures support the USITT DMX 512A signal protocol They also support RDM Remote Device Management The 5 pi...

Page 21: ...TRUE1 mains power input connector supports hot plugging and connecting and disconnecting a live power cable is an option especially if you need to shut down power urgently but it is still good practic...

Page 22: ...ill automatically reposition if knocked this option can be disabled from the menu The Pan and Tilt movements can be inverted using the menu Color The fixture has seven zones of Red Green Blue White RG...

Page 23: ...not receiving a DMX signal You can set the fixture to react in three different ways if no DMX signal is present if the fixture is being controlled by DMX but the DMX signal stops or if you apply powe...

Page 24: ...unctions MODE ESC Activate the menus or go back one level towards the top of the menu UP Scroll up or increase a number DOWN Scroll down or reduce a number ENTER Activate the control panel if it is in...

Page 25: ...ure Settings Lock Set Passcode option If you do not set a custom code the default code is 0000 Manual Control Using the Manual Control menu you can set fixed values to the fixture s control channels a...

Page 26: ...on settings using the Service Service Advanced Save Settings menu and load them using the Load Settings Preset 1 2 3 options These allow you to quickly set up the fixture in a particular configuration...

Page 27: ...aptured Scene Action when no DMX signal Capture Scene Press ENTER to capture scene Store scene for no signal PWM 600 Hz 2200 Hz 3000 Hz 4800 Hz 9600 Hz 25000 Hz Frequency of LED dimming Display Mode A...

Page 28: ...e Length Details of DMX signal Temperatures xxx Unit temperatures Fan Speeds Fan1 Error Log Xxx SERVICE Test All Running Press Enter to start test Menu or Enter to stop Test Pan only Running Test Tilt...

Page 29: ...isable Off On Units C F Offsets Tilt xxx Zoom xxx Reset Counter Power Hours Power Cycles LED Hours Max Temperature Temperature Unit Save Settings Preset 1 Preset 2 Preset 3 Factory Backup See Note 2 b...

Page 30: ...ed 9 Green 10 Blue 11 White 12 Zoom 13 Control Settings DMX Mode 2 Standard Standard Mode uses 22 DMX channels It provides 16 bit control of pan and tilt 16 bit control of dimming and a shutter with s...

Page 31: ...yer 2 also has variable speed and crossfading parameters Extended Mode also provides control of zoom and a control settings channel that lets you configure the feature and adjust settings remotely via...

Page 32: ...ovides independent RGBW color mixing on each of the fixture s seven pixels Mode 4 Pix 1 Pan 2 Pan fine 3 Tilt 4 Tilt fine 5 Dimmer 6 Dimmer fine 7 Shutter 8 Virtual color wheel 9 CTC 10 Red 11 Red fin...

Page 33: ...r wheel effect Off RGBW 0 7 0 2 7 0 Snap Color 01 Red 8 15 3 1 5 9 Snap Color 02 Amber 16 23 6 3 9 0 Snap Color 03 Warm Yellow 24 31 9 4 12 2 Snap Color 04 Yellow 32 39 12 5 15 3 Snap Color 05 Green 4...

Page 34: ...eedback On 3s hold 100 105 39 2 41 2 No function 106 117 41 6 45 9 Tilt inversion Off 3s hold 118 123 46 3 48 2 Tilt inversion On 3s hold 124 129 48 6 50 6 Pan inversion Off 3s hold 130 135 51 0 52 9...

Page 35: ...3 1 5 9 Snap Color 02 Amber 16 23 6 3 9 0 Snap Color 03 Warm Yellow 24 31 9 4 12 2 Snap Color 04 Yellow 32 39 12 5 15 3 Snap Color 05 Green 40 47 15 7 18 4 Snap Color 06 Turquoise 48 55 18 8 21 6 Snap...

Page 36: ...0 130 132 51 0 51 8 6100 133 135 52 2 52 9 6000 136 138 53 3 54 1 5900 139 141 54 5 55 3 5800 142 144 55 7 56 5 5700 145 147 56 9 57 6 5600 148 150 58 0 58 8 5500 151 153 59 2 60 0 5400 154 156 60 4 6...

Page 37: ...n Normal 3s hold 40 45 15 7 17 6 Display orientation Inverted 3s hold 46 51 18 0 20 0 No DMX Blackout 3s hold 52 57 20 4 22 4 No DMX Hold 3s hold 58 63 22 7 24 7 No DMX Stand alone 3s hold 64 69 25 1...

Page 38: ...2 38 EXO Wash User Manual Rev B No function 226 231 88 6 90 6 Return to default settings 232 237 91 0 92 9 Reset Pan Tilt 3s hold 238 243 93 3 95 3 Reset Head 3s hold 244 249 95 7 97 6 Reset All 3s ho...

Page 39: ...Amber 16 23 6 3 9 0 Snap Color 03 Warm Yellow 24 31 9 4 12 2 Snap Color 04 Yellow 32 39 12 5 15 3 Snap Color 05 Green 40 47 15 7 18 4 Snap Color 06 Turquoise 48 55 18 8 21 6 Snap Color 07 Cyan 56 63...

Page 40: ...144 55 7 56 5 5700 145 147 56 9 57 6 5600 148 150 58 0 58 8 5500 151 153 59 2 60 0 5400 154 156 60 4 61 2 5300 157 159 61 6 62 4 5200 160 162 62 7 63 5 5100 163 165 63 9 64 7 5000 166 168 65 1 65 9 4...

Page 41: ...ramp down slow fast 40 69 15 7 27 1 Sync ramp up down slow fast 70 99 27 5 38 8 Sync double flash slow fast 100 129 39 2 50 6 Random strobe pixel slow fast 130 159 51 0 62 4 Random strobe all slow fas...

Page 42: ...51 18 0 20 0 No DMX Blackout 3s hold 52 57 20 4 22 4 No DMX Hold 3s hold 58 63 22 7 24 7 No DMX Stand alone 3s hold 64 69 25 1 27 1 Fan mode Regulated 3s hold 70 75 27 5 29 4 Fan mode High 3s hold 76...

Page 43: ...German Light Products DMX control channel layout tables EXO Wash 30 User Manual Rev B 43 Reset Head 3s hold 244 249 95 7 97 6 Reset All 3s hold 250 255 98 0 100...

Page 44: ...23 6 3 9 0 Snap Color 03 Warm Yellow 24 31 9 4 12 2 Snap Color 04 Yellow 32 39 12 5 15 3 Snap Color 05 Green 40 47 15 7 18 4 Snap Color 06 Turquoise 48 55 18 8 21 6 Snap Color 07 Cyan 56 63 22 0 24 7...

Page 45: ...800 142 144 55 7 56 5 5700 145 147 56 9 57 6 5600 148 150 58 0 58 8 5500 151 153 59 2 60 0 5400 154 156 60 4 61 2 5300 157 159 61 6 62 4 5200 160 162 62 7 63 5 5100 163 165 63 9 64 7 5000 166 168 65 1...

Page 46: ...29 4 Fan mode High 3s hold 76 81 29 8 31 8 Fan mode Medium 3s hold 82 87 32 2 34 1 Fan mode Low 3s hold 88 93 34 5 36 5 Position feedback Off 3s hold 94 99 36 9 38 8 Position feedback On 3s hold 100 1...

Page 47: ...55 0 100 0 Fade 36 Pixel 4 Green Intensity 0 100 0 255 0 100 0 Fade 37 Pixel 4 Blue Intensity 0 100 0 255 0 100 0 Fade 38 Pixel 4 White Intensity 0 100 0 255 0 100 0 Fade 39 Pixel 5 Red Intensity 0 10...

Page 48: ...display on the back of the fixture as you may scratch these surfaces Use the tilt lock mechanism to hold the head in a vertical position for easier cleaning GLP Service and Support Contact information...

Page 49: ...to combustible materials 0 5 m 20 in Minimum distance to illuminated surfaces 0 5 m 20 in Installation environment Temporary or permanent indoor installation temporary outdoor installation Secondary...

Page 50: ...ifications 50 EXO Wash User Manual Rev B Included items Power cable with Neutrik powerCON TRUE1 mains input plug Dimensions and weight Length 279mm 11 0 ins Width 380 mm 15 0 ins Height 521 mm 20 5 in...

Page 51: ...German Light Products Dimensions EXO Wash 30 User Manual Rev B 51 15 Dimensions All dimensions are in millimeters...

Page 52: ......

Reviews: