background image

 
 
 

 

Operating Instructions, Parts List, Warranty, & Warranty Repair Center 

IMPORTANT!  Read  carefully  before  operating  this  tool.  Failure  to  operate  any  power  tool 
properly can result in personal injury and/or property damage!

 

Blind Rivet Setting Capacity….. Max.9/32”

 

Traction Power (Lbs)………..…………..3300

 

Air pressure (PSI) ……………..………….. 90

 

Hose Size (ID) …………………...……..… 3/8”

 

Air Inlet (NPT) ………………………..…... 1/4”

 

Rivet Size ………………………………3/16”,1/4”

 

Avg. Air Consump.(cfm).………………… 1.0

 

Overall Length ……….………..............12

-

1/2”

 

Weight (Lbs) …….…….. …..………...…... 5.3

 

 

 

Safety 

1.

 

Always wear approved eye protection.

 

2.

 

Have throttle in “off” position when connecting to air supply.

 

3.

 

Disconnect tool before performing service, changing accessories, or when not in use.

 

4.

 

Always be in a safe working distance from others when using tools.

 

5.

 

Keep tools clean and oiled for best and safest performance. 

 

6.

 

Follow instructions for lubricating and changing accessories. 

 

7.

 

Do not wear loose fitting clothing and remove watches and rings.

 

8.

 

Always use proper hose and fittings. Never use quick change couplings attached at tool. 

 

9.

 

Keep proper footing and balance at all times.

 

10.

 

Never carry tools by the hose. Keep hoses from heat, oil, and sharp edges. Check hoses 
for  weak  or  worn  condition  before  each  use,  making  certain  that  all  connections  are 
secure.

 

 

Lubrication 

Lubricate the tool daily with a good grade of air tool oil. The oil can be  applied directly into 
the air inlet of the tool and then run the tool. A rust inhibitor oil is acceptable for air tools.

 

 

Air Supply 

Tools  of  this  class  operate  on  a  wide  range  of  air  pressure.  It  is  recommended  that  air 
pressure of these tools measure 90 PSI at the tool while running free. Higher pressure and 
unclean air will shorten the tool’s life and may create a hazardous condition.

 

Water in the airline will cause damage to the tool.  Ensure that the air tank is drained daily 
Clean  the  air  inlet  filter  screen  on  at  least  a  weekly  basis.  The  recommended  hookup 
procedure can be viewed in the illustration below.

 

Model # G3499A 
Heavy Duty Pneumatic/       
Hydraulic Blind Riveter

 

Summary of Contents for G3499A

Page 1: ...Always use proper hose and fittings Never use quick change couplings attached at tool 9 Keep proper footing and balance at all times 10 Never carry tools by the hose Keep hoses from heat oil and sharp edges Check hoses for weak or worn condition before each use making certain that all connections are secure Lubrication Lubricate the tool daily with a good grade of air tool oil The oil can be appli...

Page 2: ...ssor output excessive drain on the air line moisture or restriction in air pipes or the use of hose connections of improper size or poor condition may reduce air supply Grit or gum deposits in the tool may cut power and may be corrected by cleaning the air strainer and flushing out the tool with gum solvent oil or an equal mixture of SAF 10 oil and kerosene If outside conditions are in order and t...

Page 3: ...Seal 3 15 11501 O Ring Seal 41 10550 Screw Plug 16 11511 Guide Washer 42 11549 Washer 17 11512 Ring Washer 43 10549 Sealing Washer 18 11553 Hydraulic Return Spring 44 10546 1 4 Air Inlet Fitting F 19 11557 Hydraulic Rod Guide 45 10547 Air Inlet Plug 20 10421 Lock Nut 46 10540 Washer Seal 21 115100A Screw Plug 47 11560 O Ring Seal 22 11523 Front Piston Head Disc 49 115390 Valve Tube 23 11524 Piston...

Page 4: ...articles One Year Limited Warranty GLOBAL Industrial air tools carry a limited 1 year warranty to be free from defects in material and workmanship for one year from date of purchase We will repair or replace at our discretion any defective part or unit which proves to be defective in material or workmanship during this 1 year period The foregoing obligation is GLOBAL sole liability under this or a...

Reviews: