background image

globalindustrial.ca

Distribucion Industrial Globales S DE RL DE CF

Instruction Manual

Manual de Instrucciones

Manuel d'instruction

Customer Service

US: 1-800-645-2986

Servicio de atención al Cliente

México: 01.800.681.6940

Service à la clientèle

Canada: 888-645-2986

1

Outdoor Drinking Fountain w/ Bottle Filling Station

Models 761216, 761216BK,

761216BL & 761216GN

•   All installation work must be performed by authorized

service personnel.

•   Two or more people are recommended to lift and

install the unit.

•   To avoid the risk of property damage and/or personal

injury, ensure the mounting surface is adequate to support

400 lbs.

•   Check local codes for plumbing requirements prior

to installation.

•   Refer to Rough-In Guide (page 4) prior to installation.

•   Thoroughly flush all water supply lines of all foreign

matter before connecting to the fixture.

•   Check for any leaks before use.

•   DO NOT attempt to repair or replace any part of this

fountain unless it is specifically recommended in this

manual. All other services should be referred to a

qualified technician.

•   For use with clean, clear potable drinking water only.

•   Shut-off water supply during installation to reduce the

risk of water damage.

•   Freezing Caution: Before freezing temperatures occur,

refer to the Draining and W

interization section of this

manual (page 11) for proper preparation.

•   Installation of a trap on the water drain line may be

necessary; remove trap before winterization draining.

•   Failure to follow safety warnings and/or

installation instructions will void warranty.

WARNING

Note:

 This unit is designed to be installed on the surface of an existing or new concrete slab.

Included are the necessary vandal-resistant stainless steel bolts and washers needed

to anchor this unit. Installer must provide a 1-1/2” PVC drain line (if applicable) and water supply

line. All connections are made inside the item through the access doors, as shown in the drawings.

It is recommended to install a shut-off valve (not included) on the water supply. 

Summary of Contents for 761216

Page 1: ...r or replace any part of this fountain unless it is specifically recommended in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce the risk of water damage Freezing Caution Before freezing temperatures occur refer to the Draining and Winterization section of this manual...

Page 2: ...in w Bottle Filler 1 2 BOTTLE FILLER PEDESTAL 1 2 BOTTLE FILLER PEDESTAL SPOUT DRAIN PAN DRINKING FOUNTAIN BUBBLER DRAIN PUSH BUTTON PEDESTAL ARM BASE COLOR OPTIONS WWW GLOBALINDUSTRIAL COM SS316 SS316 GREEN SS316 BLACK SS316 BLUE 3 HARDWARE BAG ...

Page 3: ...ottle Filler REQUIRED TOOLS Safety Gloves 15 17mm Wrench Hammer Safety Glasses Adjustable Wrench Phillips Head Screwdriver Ref Qty Descrip on Ref Qty Descrip on P1 1 Bubbler P9 1 Elbow Drain Connector P2 2 Inlet Adapter P10 1 T Shape Drain Connector P3 1 Union T Connector P11 2 Drain Tubing P4 1 Straight Flow Check Valve P12 1 Offset Drain Tubing P5 4 1 4 O D Water Inlet H1 1 Torx Key Wrench P6 2 3...

Page 4: ...8 O D UNPLATED COPPER TUBE CONNECT SHUT OFF VALVE BY OTHERS B ACESS PANEL 7 X 20 B 2 ACCESS PANEL 7 X 7 C REMOVABLE BOTTOM COVER Rough In Guide See Page 11 for Draining and Winterization Actual product configuration may vary based on model ordered 14 355mm 11 1 2 300mm 60 1 4 1531mm 36 1 2 922mm 10 1 4 260mm B B 2 7 177mm 5 1 2 146mm 20 511mm 20 1 2 526mm 5 1 2 133mm 7 177mm 8 1 4 210mm INSIDE OPE...

Page 5: ... may be necessary check local plumbing codes WARNING The fountain is rated for inlet water pressure of 20 105 PSI A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI Any damage caused by reason of connecting this product to supply line pressure higher than 105 PSI will void warranty Flat head anti theft screw M6 x 10 qty 24 1 REMOVE ACCESS PANELS REMOVE To gain a...

Page 6: ...d using provided anchor kit H3 mounting hardware 2 INSTALL BUBBLER 2a Unscrew and remove nut and washers from Bubbler P1 2b Locate the hole on the drinking fountain pan surface Align and sandwich with the two washers and tighten the nut to secure the bubbler 2c Bubbler is now properly installed 4 ATTACH BOTTLE FILLER TO PEDESTAL Using a phillips head screwdriver assemble the bottle filler to the p...

Page 7: ...must comply with local codes Though the rear access windows connect water inlet lines as illustrated below P6 31 1 2 INSTALL SHUT OFF VALVE NOT INCLUDED Connect P5 to Spout Connect P5 to Push Button P5 6 1 4 P5 39 1 2 Connect Inlet Adapter P2 to Union T Connector P3 P5 25 1 2 Connect P5 to Bubbler Connect P6 to Straight Flow Check Valve P4 See Fig 1 on next page P5 25 1 2 P4 P3 P2 ...

Page 8: ... TO RELEASE TUBE OPERATION OF QUICK CONNECT FITTINGS NOTE WATERFLOW DIRECTION If drinking fountain is being installed in areas where cold temperatures may occur wrap pipe insulation P7 around all water inlet lines Installation of a trap on the water drain line may be necessary check local codes Always remove trap before winterization draining CAUTION Before freezing temperatures occur see Draining...

Page 9: ...lines as illustrated below NOTE All drain lines attach with quick connect connections Installation of a trap on the water drain line may be necessary check local codes P11 28 1 8 P11 16 3 4 P12 P10 P9 P8 Connect P8 to Bottle Filler Drain and insert P12 Connect P9 to Drinking Fountain Drain and insert P11 Connect all 3 Drain Tubes to P10 Confirm with local codes for trap and other drainage requirem...

Page 10: ...nnections for leaks and proper operation Reinstall all 4 access panels using the 24 M6 x 10 flat head anti theft screws preciously removed from the fountain WARNING Flush all water supply lines thoroughly before initial use SIDE VIEW FRONT VIEW P12 P11 28 1 8 P8 P10 P9 P11 16 3 4 Confirm with local codes for trap and other drainage requirements ...

Page 11: ...EAM HEIGHT ADJUSTMENT To adjust the water stream height insert a small flathead screwdriver through the access hole in the center of the push button and turn the adjustment screw Turn clockwise to raise the stream height and counterclockwise to lower the stream height For best adjustment the stream should be approximately 1 1 2 above the top of the bubbler see FIG 3 FIG 3 1 1 2 Before freezing tem...

Reviews: