background image

 

1

Wall Mounted Water Bottle Refilling Station

052120

globalindustrial.ca

User's manual

Manual del usuario

Manuel de l'utilisateur

Customer Service

US: 1-800-645-2986

Servicio de atención al Cliente

US: 1-800-645-2986

Service à la clientèle

Canada: 888-645-2986

        WARNING

  

 Keep compressor in upright position for 24 hours 

before water connections and initial power-on. Failure 

to do so will void warranty.

• For indoor commercial use only.

•  All installation work must be performed by authorized 

service personnel.

•  Two or more people are recommended to lift and install 

the unit.

•  To avoid the risk of property damage and/or personal 

injury, mount the unit to a flat finished wall surface with 

adequate support.

•  

Check local codes for plumbing requirements prior  

to installation.

•  Prior to initial installation, install a shut-off valve (not 

included) from the water supply.

•  Thoroughly flush all water lines and fittings of all foreign 

matter before connecting to the cooler. Failure to do so 

will void warranty.

•  Check for any leaks before initial operation.

•  DO NOT attempt to repair or replace any part of your 

appliance unless it is specifically recommended in 

this manual. All other services should be referred to a 

qualified technician.

• For use with clean, clear potable drinking water only.

•  Shut-off water supply during installation to reduce risk 

of water damage. 

•  

Ensure proper ventilation by allowing appropriate 

clearance of housing louvers to the wall on each side 

of the cooler, as specified in rough-in guide.

•  NEVER wire the compressor directly to an electrical supply.

• DO NOT allow children to play with the appliance.

•  Interior of unit may contain sharp edges. Wear gloves 

when handling or servicing unit.

• Failure to follow installation instructions will void warranty.

Note:

 These fixtures are intended for indoor commercial 

use only. Do not expose to freezing temperatures. 

The grounding of electrical equipment to water lines is 

a common procedure. This grounding may be in the 

building or occur away from the building. This grounding 

can cause electric feedback into the water cooler 

creating an electrolysis which creates a metallic taste or 

causes the water metal content to increase. Connect to 

water supply using non-conductive materials.

Model 761218

Read this manual thoroughly prior to 

installation, operation or maintenance. 

Keep these instructions in a safe location 

for future reference. For questions, visit 

globalindustrial.com or contact Customer 

Service at 1-800-645-2982.

Summary of Contents for 761218

Page 1: ...nded in this manual All other services should be referred to a qualified technician For use with clean clear potable drinking water only Shut off water supply during installation to reduce risk of wat...

Page 2: ...b Capacity Flat Head Wall Anchors appropriate for your wall type 10 11 Flat Head Anchor Screws WARNING Review manual thoroughly and verify rough ins before installation Keep these instructions in a sa...

Page 3: ...3 User s Manual Wall Mounted Water Bottle Refilling Station Check local codes for plumbing requirements prior to installation...

Page 4: ...8mm Lg Phillips Flat Head Screw H6 1 Filler Access Door Key WARNING Assembly and installation of equipment should be performed by 2 people 1 2 H2 H1 1 2 3 Remove Lower Cover Using the Anti Theft Screw...

Page 5: ...p Assembly right side up and carefully feed connections though the Stainless Steel Pan hole Ensure gasket is seated properly and lies flat Attach Bottle Filler Top Assembly to the Stainless Steel Pan...

Page 6: ...Connectors Connect white Activation Connector C to Power Supply C in the Cooling System Connect white Activation Connector A to Power Supply A Connect the 2 Activation Connectors B to the Solenoid Val...

Page 7: ...om brackets onto the wall using appropriate anchors Hanging assembled unit to wall Carefully hang assembled bottle filler onto the wall by lowering onto both top and bottom wall mount brackets 8 9 Not...

Page 8: ...filter into the filter head by turning clockwise until locked into place Turn both water control valves to the open position Check all connections for leaks If leaks are detected ensure all connection...

Page 9: ...please read all instructions and warnings Installation service and maintenance should be All parties must follow proper safety procedures and precautions at all times Do Not Install Damaged Products...

Page 10: ...have sputter due to air in the water lines this will be eliminated once air is purged from all water lines To operate bottle filler verify proper dispensing by placing bottle hand or any opaque objec...

Page 11: ...filter size if a filter is not being used Note For filter capacities higher than 3600 gallons select 3600 4 Tap ENTER button to confirm your filter size Resetting Bottle Counter 1 Press and hold ENTER...

Page 12: ...ween CHG FLT entire time Issue Possible Cause Suggested Action Water temperature not cool The thermostat is set too high Lower the water temperature on the thermostat see Adjusting Settings page 10 No...

Reviews: