ELECTRONIC CARD
OPERATION CHECK
General informations:
---
Related topics:
---
1
11
1
10
1
1
10
To make this tests it is necessary to have:
– The key in the «ON» position
– Connector (1) connected to the card.
In this situation the pilot lamp should come on.
A) Card supply
This check is done with the tester in Voltmeter func-
tion (Volt DC 0 ÷ 20), with the black ferrule on termi-
nal 1 and the red ferrule on terminal 11 of the wiring
connector (1).
The reading on the tester shows the battery’s voltage.
B) Safety and service supply check
This check is done with the tester in Voltmeter func-
tion (Volt DC 0 ÷ 20), with the black ferrule to earth
and the red ferrule on terminal 10 of the wiring con-
nector (1).
C) Checking the operation of the self-setting
protection
By connecting terminal 10 of the connector
(1)
to the
frame’s earth, the pilot lamp should go out due to the
protection cutting in; eliminating the connection to
earth, the pilot lamp should come on again.
NOTE
During this test, the self-setting protection reaches
very high temperatures (around 160 °C) which are to
be considered normal. Similarly, there might be some
smoke inside the transparent box which is due to the
overheating of the powder inside.
WARNING! Do not touch this component of
the card until it has cooled down.