Important Safety Instructions
SAVE THESE INSTRUCTIONS.
This manual contains important SAFETY WARNINGS and
OPERATING INSTRUCTIONS. You will need to refer to it before attempting any
installation or maintenance.
ALWAYS
keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property
damage, serious injury, or death.
•
ALWAYS
disconnect the pump from the power source before servicing or making
adjustments.
•
NEVER
handle the pump or motor with wet hands or when standing on a wet or damp
surface while the pump is plugged into the power source.
•
MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE.
This pump is
wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain
that it is only connected to a properly grounded, 3-prong receptacle. If you have a 2-
prong receptacle, have a licensed electrician replace it with a 3-prong receptacle
according to local codes and ordinances.
•
NEVER
bypass grounding wires or remove the ground prong from the plug.
•
DO NOT
use an extension cord. The electrical outlet should be within the length of the
pump’s power cord, and at least 4 feet above the floor level to minimize potential
hazards from flood conditions.
•
DO
protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
•
MAKE SURE
the supply circuit has a dedicated fuse or circuit breaker rated to handle
the power requirements noted on the nameplate of the pump.
•
DO NOT
use the power cord or strain relief to carry the pump. Use the pump handle.
•
DO NOT
pull on the float switch cord.
•
DO NOT
operate the pump or control unit if it has been damaged in any way.
•
DO NOT
use sump pumps in pits handling raw sewage, salt water, or hazardous liquids.
This pump is for ground water use only.
•
DO NOT
use in continuous duty applications such as fountain ponds. This pump is rated
for intermittent use only.
•
DO NOT
disassemble the pump or float switch. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to the
manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
• When installing or replacing a primary sump pump you should also install a battery
backup sump pump system.
Risk of electric shock. To reduce this risk, observe the
following precautions
.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
Cast Iron Sump Pumps
Instruction Manual &
Safety Warnings
Items Included:
Pump with vertical float switch
You may also need:
A 1-1/2” PVC pipe adapter to screw into the discharge hole on top of the pump
1-1/2” rigid PVC pipe to connect to the existing plumbing
A check valve or rubber union
PVC pipe cleaner and cement
Wire ties or hose clamps
Model CIS-33V & CIS-50V
!
WARNING
!
CAUTION
Specifications
1/3 HP Model CIS-33V
1/2 HP Model CIS-50V
GPH @ 0’
4000
4300
GPH @ 10’
3200
3840
Pump diameter
9.5”
9.5”
Volts
115V, 60Hz
115V, 60Hz
Amps
5.0
5.5