Page
15
of
30
Input Impedance Settings
Most cartridge manufacturers provide the recommended load impedance for their
cartridges. The Athens 2’s inputs should be set to match this recommended figure as
closely as possible.
4 dip switches adjust the input impedance and more than one dip switch can be
turned on at the same time.
The 4
dip switches that adjust the input impedance are marked on the panel as ‘Z’.
The picture below shows the required position of the Z dip switches for specific input
impedances.
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
Impedance = 47 KOhms
Impedance = 1000 Ohms
Impedance = 470 Ohms
Impedance = 220 Ohms
Impedance = 100 Ohms
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
Impedance = 320 Ohms
Impedance = 180 Ohms
Impedance = 90 Ohms
Impedance = 130 Ohms
Impedance = 76 Ohms
Impedance = 56 Ohms
Impedance = 150 Ohms
Impedance = 80 Ohms
Impedance = 60 Ohms
Impedance = 68 Ohms
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
5
6
7
8
LEFT CHANNEL Z DIP SWITCHES
RIGHT CHANNEL Z DIP SWITCHES