Page
15
of
29
RESET TO FACTORY DEFAULT SETTINGS
To reset the device to a base default configuration simply hold down the update
button continuously for 13 seconds. The LCD display will show
‘Reset!’ when the
defaults have been applied.
The default settings are as follows:
Ring CH
(Dante 1)
Pres CH
(Dante 2)
CH Colour
(1
– Red) (2 – Green) (3 – Blue) (4 – Purple)
LS On/off
On
Brightness
High
LS level
10
CALLING FROM OTHER BEATRICE DEVICES
A standard 20kHz sinewave tone is how the Beatrice LH listens for call detection.
This is standard among all Glensound Beatrice devices as well as some other
intercom manufacturer
’s products.
When the Beatrice LH receives a call, the light house LEDs will flash (colour based
on what is set in the menu) and the device will ring for a few seconds.