1.2.

 

GENERAL OPERATION 

 

Spindle 

 

The air spindle on the door controls the primary air to the 
base of the fire. This controls the burn rate of the fire. 

 

 

 

A tool for opening and closing the air spindle is supplied with 
the heater. This can be used in instances when the spindle 
control is too hot to touch. Alternatively, a glove or equivalent 
can be used to adjust the air spindle. 

 

 

 

Air Wash 

 

A 2mm gap at the top of the door allows additional air to 
enter the firebox, washing over the door glass keeping it clean 
while also supplying necessary oxygen to the fire when the air 
spindle has been fully closed. 

If the draft is too high or low with the spindle completely shut, 
the 2mm gap can be adjusted by loosening the two grub 
screws in the top of the door (high-lighted in the image below) 
with the Allen key supplied, adjusting the metal strip 
accordingly and re-tightening the screws. 

For example, an installation in a two-storey house with a tall 
flue could have a very high draft. To reduce the draft, the gap 
on top of the door could be reduced to 1mm. 

Warning: Do not close this air gap completely as it will restrict 
the draft too much. If the draft is too restricted, the fire will 
produce a lot of smoke and cause the glass to blacken. 

 

 

 

Door Handle 

 

Warning: The door handle may get hot if the appliance has 
been left in the high burn setting for an extended period. Use 
a protective glove to open. 

Open the air spindle before opening the door to eliminate the 
chance of backdraft and smoke entering the room. 

Spindle 

Summary of Contents for Nectre 15 LE

Page 1: ...re 15 LE Operating Instructions Keep these instructions for future reference Glen Dimplex Australia proudly supports the activities of Landcare Australia through its membership of the AHHA Legs Pedest...

Page 2: ...MABLE LIQUIDS OR AEROSOLS TO START OR REKINDLE THE FIRE WARNING DO NOT USE FLAMMABLE LIQUIDS OR AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OPERATING WARNING DO NOT STORE FUEL WITHIN HEATER...

Page 3: ...letely shut the 2mm gap can be adjusted by loosening the two grub screws in the top of the door high lighted in the image below with the Allen key supplied adjusting the metal strip accordingly and re...

Page 4: ...Once the fire is established close the door Do not leave the appliance unattended while the door is open 1 6 RUNNING THE APPLIANCE Maximum Heat Output This setting is not the most energy efficient as...

Page 5: ...mbustible materials 1 9 FLUE CHIMNEY FIRE If a flue chimney fire occurs Shut spindle fully to smother the fire Do not use the appliance after a flue fire until an accredited installer has assessed the...

Page 6: ...sulates the base helping to maintain a high temperature for combustion Also if all the ash has been removed from the firebox it can affect the supply of air to the base of the fire Insufficient flue d...

Page 7: ...erse to fit the new baffle plate see image below for correct baffle placement 2 4 ADJUSTING THE DOOR If the door does not close firmly the latch can be adjusted The latch is fastened onto the door wit...

Page 8: ...ein shall repair or replace without cost to the original customer any part thereof which shall be returned to our factory transportation charges prepaid and which our inspection shows would prevent op...