Installation

Preparing for installation

CAUTION:

 Always shut off the water supply before 

removing an existing faucet or replacing any part of a 
faucet. Open the faucet handle to relieve water pressure 
and ensure that the water is completely shut off.

Installing the valve body and 
removing the plaster guard

 

Shut off the water supply to the tub and 
shower.

 

Verify that the hole sizes and positions of the 
holes in the wall are correct

  

 

The shower and tub spout outlet holes 
should be 1-1/4 in. diameter

.

 

 

Refer to Step 2 for valve access hole 
dimensions.

 

The recommended valve depth to the 
finished wall is 1-1/2 in. min. to 
2-1/2 in. max. 

 

Ensure that the valve body (D) cover is flush 
with the finished exterior surface of the wall. 
Position the valve body (D) correctly in the 
wall with the side marked "UP" pointing up. The 
8 in. minimum from the valve body (D) to the tub 
spout (J) is required for proper operation.   

A. Thin Wall Installation
“Thin Walls” are usually built up with materials 
such as fiberglass tub surrounding them and will 
be the main source of support for the valve. The 
plaster guard (L) remains attached to the valve.

B. Thick Wall Installation
“Thick Walls” are usually built up with materials such 
as cement board, drywall, tile, etc. The plaster guard 
(L) is positioned so that it is flush with the finished 
wall. This ensures that the valve will be at the correct 
position to accept the trim. The depth for the valve 
body (D) in wall is measured from the center of the 
shower outlet to the finished wall surface. The 
accepted depth distance is 1-1/2 in. to 2-1/2 in.. When 
the depth distance is 1-1/2 in. to 2 in., there will be 
interference between the plaster guard (L) and 
escutcheon (E). It is recommended that you remove
the plaster guard (L) after the wall installation.

Unscrew the screws (K), and remove the plaster 
guard (L).

NOTE: 

Be sure to position the valve body (D) correctly in 

the wall, with the side marked "UP" facing upward. 

HOMEDEPOT.COM/GLACIERBAY

Please contact 1-855-HD-GLACIER for further assistance.

       30 in.

Tub & Shower

8 in. Min.

      48 in. 

Shower Only

1 1/4 in. Diamter 

1 1/4 in

.

 Diameter

       48 in. 

Tub & Shower

Refer to 
the step 2

       30 in. 

Shower Only

D

1-1/2 in. to 2-1/2 in.

Finished wall

6 in. dia.

D

L

3-3/8 in. to 6 in. dia.

Finished wall

D

L

L

K

Summary of Contents for 108-191

Page 1: ... quality products designed to enhance your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Glacier Bay Model 874X 0001 SKU 108191 THD Questions problems missing parts Before returning to the store call Glacier Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT C...

Page 2: ... resonance materials Clamping or strapping can help prevent these noises DO NOT USE PEX tubing from the valve to the tub spout Tools and Hardware Required 3 Warranty LIMITED LIFETIME WARRANTY Glacier Bay products are manufactured with superior quality standards and workmanship and are backed by our limited lifetime warranty Glacier Bay products are warranted to the original consumer purchaser to b...

Page 3: ...his product If you are replacing your plumbing valve please review the four common plumbing methods illustrated below COPPER IPS PEX and CPVC Remove the existing handle and valve trim before replacing your valve Please follow all local building and plumbing codes A COPPER Before soldering remove the cartridge stop valves from the valve Torch Lead free solder Kit Key hole saw Wire brush All install...

Page 4: ...r Flathead screwdriver S I L I C O N E Silicone sealant B IPS Key hole saw Flashlight C PEX COPPER Safety goggles Thread sealant tape Tube cutter Strap wrench Adjustable wrench Measuring tape Thermometer Phillips screwdriver Flathead screwdriver S I L I C O N E Silicone sealant Key hole saw Flashlight Full circle crimping tool Pipe wrench COPPER COPPER ...

Page 5: ... Adjustable wrench Measuring tape Thermometer Phillips screwdriver Flathead screwdriver S I L I C O N E Silicone sealant Key hole saw Flashlight CPVC cleaner Pipe Joint Compound CPVC cement Pipe Joint Compound HOMEDEPOT COM GLACIERBAY Please contact 1 855 HD GLACIER for further assistance COPPER COPPER ...

Page 6: ...t Description Quantity A 1 B Shower arm 1 C Shower head 1 D Valve body 1 E Escutcheon 1 F Handle 1 G Screw 1 H Index 1 Shower flange I Plug 1 J Tub spout 1 K Screw 2 L Plaster guard 1 M Escutcheon screw 2 N Protective cap 1 D E F G I J N M A B C L K H ...

Page 7: ...g them and will be the main source of support for the valve The plaster guard L remains attached to the valve B Thick Wall Installation Thick Walls are usually built up with materials such as cement board drywall tile etc The plaster guard L is positioned so that it is flush with the finished wall This ensures that the valve will be at the correct position to accept the trim The depth for the valv...

Page 8: ...ish to install the tub outlet insert the plug I into the bottom of the valve body D 4 Back to back installation NOTE Never install the valve body D upside down If the hot and cold inlets are reversed hot on right and cold on left remove the screw 1 inverter 2 sleeve 3 and bonnet 4 from the valve body D with reversed supply connections Rotate the cartridge 5 180 so H appears on the right Install th...

Page 9: ... the full on mixed position Turn on the hot and cold water supply lines and allow the water to flow from the outlets for one minute or until all foreign matter has been flushed out Check for leaks Shut off the water at the faucet and supply lines Remove the handle F NOTE Be sure to position the plaster guard L correctly onto the valve body D with the side marked SHOWER facing upward HOMEDEPOT COM ...

Page 10: ...pout outlet 1 not included in a clockwise direction as shown Connect the tub spout outlet pipe the tub spout outlet pipe should project 3 15 16 in to 4 3 32 in from the finished wall to the lower pipe elbow 2 not included Tighten the elbow and tub spout outlet pipe connections with a strap wrench 8 Installing the tub spout Wrap thread sealant tape around the pipe threads of the tub spout J outlet ...

Page 11: ...he center of the shower outlet to the finished wall surface is 1 1 2 in to 2 in NOTE The limiter on the valve can be set to allow partial or full access to hot water by limiting how far the handle can be turned to the hot side of the valve The limiter is typically set at the factory to allow only warm water to pass through the valve Follow the directions in this section if you wish to adjust the a...

Page 12: ...djust the red limit stop ring 1 in a counterclockwise direction and reinstall the red limit stop ring 1 onto the cartridge assembly 2 B Removing the red limit stop ring Remember the position of the red limit stop ring 1 on the cartridge assembly 2 Remove the red limit stop ring 1 from the cartridge assembly 2 NOTE A thermometer not included can be held in the running water to aid in reaching the d...

Page 13: ...ise to turn off the water before you install the handle 11 Installing the escutcheon and handle Install the escutcheon E onto the valve body D using the escutcheon screws M Place the handle assembly F onto the valve body D and secure it with the screw G Use a Phillips screwdriver to tighten the escutcheon screws M and the screw G Insert the index H into the handle F HOMEDEPOT COM GLACIERBAY Please...

Page 14: ...er normally flows through the tub spout J To activate the shower turn the valve on and pull the knob 1 up Hold the knob 1 until the water flows continuously from the shower arm B Check for leaks Shut off the water at the faucet and supply lines 14 Care and Cleaning To clean wipe down with a damp cloth and dry with a towel Do not use abrasive cleaners steel wool or harsh chemicals when cleaning thi...

Page 15: ...sider the causes below The pipe used between the valve and the tub spout is not 1 2 in IPS or the COPPER pipe is incorrect The distance between the valve and the showerhead is less than 48 in There is a restriction between the valve and the tub spout The valve is installed upside down Change the pipe to IPS or COPPER The distance from the showerhead and valve moved to at least 48 in Remove the tub...

Page 16: ...e Part Description Part Number 1 RP38046 2 Shower arm RP38019 3 5 Plug RP70365 6 Cartridge RP22017 8 O ring RP60091 Shower flange Part Description Part Number 16 Spout RP33052 9 Sleeve RP80297 10 Escutcheon RP80191 11 Escutcheon screw RP50066 12 Inverter RP70425 13 Handle RP13172 14 Handle screw RP50108 15 Index RP10044 4 O ring RP60101 Shower head RP38301 7 Bonnet nut RP7032701 3 5 7 6 8 4 2 1 11...

Page 17: ...issing parts Before returning to the store call Glacier Bay Customer Service 8 a m 7 p m EST Monday Friday 9 a m 6 p m EST Saturday 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT COM GLACIERBAY Retain this manual for future use ...

Page 18: ...Visítanos en Internet para ver nuestra línea completa de productos disponibles para las necesidades de mejoras de tu hogar Gracias por elegir a Glacier Bay GRACIAS Modelo núm 874X 0001 SKU núm 108191 Problemas preguntas o piezas faltantes Antes de regresar a la tienda llama al servicio al cliente de Glacier Bay de lunes a viernes entre 8 a m y 7 p m y los sábados entre 9 a m y 6 p m hora estándar ...

Page 19: ... materiales de alta resonancia La sujeción o anclaje son métodos para evitar estos ruidos NO USES tuberías PEX desde la válvula al caño de la bañera Garantía GARANTÍA LIMITADA DE POR VIDA Los productos de Glacier Bay están fabricados con normas y mano de obra de calidad superior y están respaldados por nuestra garantía de por vida limitada Glacier Bay garantiza al comprador consumidor original que...

Page 20: ...Si estás cambiando tu válvula de plomería consulta los cuatro métodos comunes que aparecen más abajo COBRE IPS PEX y CPVC Quita la manija y el regulador de válvula preexistentes antes de reemplazar tu válvula Cumple con todos los códigos locales de construcción y plomería A COBRE Antes de soldar quita el cartucho y las válvulas de cierre del cuerpo de la válvula Soplete Kit de alambre de soldadura...

Page 21: ...abeza plana S I L I C O N E Sellador de silicona Serrucho de punta Linterna C PEX COBRE Gafas de seguridad Cinta selladora para roscas Cortador de tuberías Llave de correa Llave ajustable Cinta métrica Termómetro Destornillador Phillips Destornillador de cabeza plana S I L I C O N E Sellador de silicona Serrucho de punta Linterna Herramienta para engarzar de círculo completo Llave para tubería COB...

Page 22: ... correa Llave ajustable Cinta métrica Termómetro Destornillador Phillips Destornillador de cabeza plana S I L I C O N E Sellador de silicona Serrucho de punta Linterna Limpiador CPVC Pipe Joint Compound Cemento CPVC Pipe Joint Compound HOMEDEPOT COM GLACIERBAY Para obtener asistencia llama al 1 855 HD GLACIER COBRE COBRE ...

Page 23: ...azo de la ducha 1 C Cabezal de la ducha 1 D Cuerpo de la válvula 1 E Placa protectora 1 F Llave 1 G Tornillo 1 H Índice 1 Brida de la ducha I Tapón 1 J Caño de la bañera 1 K Tornillo 2 L Protector de yeso 1 M Tornillo de la placa protectora 2 D E F G I J N M A B C L K H N Tapa protectora 1 ...

Page 24: ...antan con materiales tales como cerramiento de bañera de fibra de vidrio y serán la principal fuente de apoyo para la válvula El protector de yeso L permanece unido a la válvula B Instalación en pared gruesa Las paredes gruesas usualmente se construyen con materiales tales como placas de cemento drywall losa etc El protector de yeso L se coloca de forma tal que esté al ras con la pared acabada Est...

Page 25: ...as instalar la salida de la bañera inserta el tapón I en la parte inferior del cuerpo de la válvula D 4 Instalación de parte posterior con posterior NOTA Nunca instales el cuerpo de la válvula D al revés Si las entradas de agua caliente y fría se revierten caliente a la derecha y fría a la izquierda quita el tornillo 1 el inversor 2 la funda 3 y el bonete 4 del cuerpo de la válvula D con conexione...

Page 26: ...sición de mezclado completo Abre las líneas de suministro de agua caliente y fría y deja que salga el agua durante un minuto o hasta que expulse todos los desechos Verifica que no haya fugas Cierra la llave de agua en el grifo y las líneas de suministro Quita la llave F NOTA Asegúrate de colocar el protector de yeso L correctamente sobre el cuerpo de la válvula D con el lado de la marca SHOWER duc...

Page 27: ...en dirección de las manillas del reloj tal como muestra el diagrama anterior Conecta la tubería de salida del caño de la bañera la tubería de salida del caño de la bañera debe salir de 10 0 cm a 10 4 cm de la pared terminada al codo de la tubería inferior 2 no incluido Aprieta los codos y las conexiones de la tubería de salida del caño de la bañera con una llave de correa 8 Cómo instalar el caño d...

Page 28: ...ndidad que se mide desde el centro de la salida de la ducha hasta la superficie de la pared acabada es de 3 8 cm a 5 1 cm NOTA El limitador de la válvula puede configurarse para permitir acceso parcial o total al agua caliente al limitar hasta dónde puede girarse la manija en el lado del agua caliente de la válvula El limitador usualmente está configurado de fábrica para permitir sólo el paso de a...

Page 29: ...eseada temperatura máxima del agua Para agua más fría ajusta el aro de retención del límite rojo 1 hacia la derecha y vuelve a instalarlo 1 en el conjunto del cartucho 2 Para agua más caliente ajusta el aro de retención del límite rojo 1 hacia la izquierda y vuelve a instalarlo 1 en el conjunto del cartucho 2 NOTA Puede colocarse un termómetro no incluido en el agua corriente para ayudar a alcanza...

Page 30: ...nistro de agua antes de instalar la manija 11 Cómo instalar la placa protectora y la llave Instala la placa protectora E en el cuerpo de la válvula D usando los tornillos para la placa protectora M Coloca el ensamblaje de la llave F en el cuerpo de la válvula D y asegúralo con el tornillo G Usa un destornillador Phillips para apretar los tornillos del escudete M y el tornillo G Inserta el índice H...

Page 31: ...normalmente por el caño de la bañera J Para activar la ducha abre la válvula y hala la perilla 1 hacia arriba Sostén la perilla 1 hasta que el agua corra de forma continua desde el brazo de la ducha B Verifica que no haya filtraciones Cierra la llave de agua en el grifo y las líneas de suministro HACIA ARRIBA PARA LA DUCHA 31 Cuidado y limpieza Para limpiar usa un paño húmedo y seca con una toalla...

Page 32: ...s siguientes causas La tubería usada entre la válvula y el caño de la bañera no es de 1 2 plg Las tubería IPS o de COBRE son incorrectas La distancia entre la válvula y el cabezal de la ducha es de menos de 1 22 m Hay una restricción entre la válvula y el caño de la ducha La válvula está instalada al revés Cambia la tubería a IPS o COBRE La distancia entre la válvula y el cabezal de la ducha varía...

Page 33: ...Descripción Número de Pieza 1 RP38046 2 Brazo de la ducha RP38019 3 5 Tapón RP70365 6 Cartucho RP22017 8 Aro tórico RP60091 Brida de la ducha Pieza Descripción Número de Pieza 16 Caño RP33052 9 Funda RP80297 10 Placa protectora RP80191 11 Tornillo de la placa protectora RP50066 12 Invertidor RP70425 13 Llave RP13172 14 Tornillo de la llave RP50108 15 Índice RP10044 4 Aro tórico RP60101 Cabezal de ...

Page 34: ...gresar a la tienda llama al servicio al cliente de Glacier Bay de lunes a viernes entre 8 a m y 7 p m y los sábados entre 9 a m y 6 p m hora estándar del Este 1 855 HD GLACIER 1 855 434 5224 HOMEDEPOT COM GLACIERBAY Conserva este manual para uso futuro ...