Specifications
GL-SP60 Outlook
Users’ Manual
GL-SP60
1. The warranty period will last for two years since you buy the products. If the
product fails or malfunctions under the proper installation and normal usage within
the warranty period, please send it back to our company with our RMA approval or
contact your local distributors for free repairing or replacing services.
2. Please do not add/remove any electrical components to/from the
products or change/tamper the original electrical design without our permission.
3. Please do not add/remove any mechanical components to/from
the products or change/tamper the original mechanical design without our
permission.
4. lease store or use the products in an environment meeting the
temperature and humidity conditions designated by the product specifications.
Please do not uncover the GL-SP60 series LED products, lest waterproof and
dustproof become invalid.
5. To avoid any electrical shock or functional damage, please do not
insert any foreign objects into the products.
6. For further information, please contact us.
CAUTIONS
GL-SP60
100V-240V~ 50-60Hz 76W IP65
1. Before installation,
please turn off the
power switch for the
existing lamp.
4. Please insulate properly the wires/terminals
of the AC voltage source, screw tightly the
GL-SP60 series LED products onto a wall
or a stand, and adjust freely the lighting
angle in accordance with individual needs.
5. Please turn on the AC voltage source to
check whether the GL-SP60 series LED
products can work normally. If not, please
check carefully whether all the above
installation steps are taken and usage
conditions are met.
Installation Steps
Optical
Mechanical and Dimension
Electrical
Temperature Condition
Model No.
CCT (Typical)
GL-SP60-WW
(Warm White)
GL-SP60-CW
(Cool White)
Luminous Flux (lm)
Typical Luminous Efficacy
CRI (Ra)
Beam Angle
Net. Weight
Power Factor
Cover
3000 K
6000 K
2700 lm
3800 lm
36 lm / W
50 lm / W
> 80
> 75
30° / 60° (Optional)
Outline Dim.
450 × 305 × 135 (mm)
7.6 (Kgs)
76 W
> 0.9 for 115V AC; > 0.8 for 230V AC
-20 °C
-
+40 °C
-40 °C
-
+85 °C
Clear
Typical Power consumption
Input Voltage
Operating Temperature
Storage Temperature
100 – 240V AC
(L) Brown
(N) Blue
Green / Yellow
2. Please make sure that both
the AC voltage source and
the power connector are
compatible with the
GL-SP60series LED
products.
3. The GL-SP60 series LED products feed only on an AC voltage
source having an appropriate output voltage designated by the
product specifications. Please connect respectively the Brown,
Blue, and Green/yellow wires/terminals at the rear side of the
GL-SP60 series LED products to the Line (L), Neutral (N), and
Frame Ground (FG) wires/terminals of the AC voltage source.
It depends on the model in use that the Brown, Blue, and
Green/Yellow wires may be not screwed or screwed
internally onto a terminal block. Misusing an
inappropriate voltage source may lead to
product damage.
Thank you for choosing the GL-SP60
series LED products. Please install
and use the products according to the
following directions to ensure the
normal function and proper operation
of the products. If not to follow these
instructions to properly install and
normally use the products, you will
not get the warranty-committed
compensation or protection.
GlacialLight will not take any
responsibility for any product damage
caused by improper installation or
abnormal usage.
305 mm
450 mm
135 mm
LED GL-SP60 IP65
CAUTION
CLASS 2 LED LIGHT
Do not stare at the beam.
Installation procedure should be undertaken by qualified technical personnel.